Quoting Taniya Das (2021-12-20 08:43:55) > The registers for some clocks in the SOC area, which are under the power > domain are required to be enabled before accessing them. During the > clk_summary if the power-domains are not enabled they could result into > NoC errors. > > Thus ensure the register access of the clock controller is done with > pm_untime_get/put functions. > > Signed-off-by: Taniya Das <tdas@xxxxxxxxxxxxxx> > --- Applied to clk-next