Hi Alain On 12/18/21 10:11 PM, Alain Volmat wrote: > In order to avoid having duplicated addresses within the DT, > only have one unit-address per clockgen and each driver within > the clockgen should look at the parent node (overall clockgen) > to figure out the reg property. Such behavior is already in > place in other STi platform clock drivers such as clk-flexgen > and clkgen-pll. Keep backward compatibility by first looking > at reg within the node before looking into the parent node. > > Signed-off-by: Alain Volmat <avolmat@xxxxxx> > --- > v2: identical to v1 > > drivers/clk/st/clkgen-mux.c | 11 +++++++++-- > 1 file changed, 9 insertions(+), 2 deletions(-) > > diff --git a/drivers/clk/st/clkgen-mux.c b/drivers/clk/st/clkgen-mux.c > index ce583ded968a..ee39af7a0b72 100644 > --- a/drivers/clk/st/clkgen-mux.c > +++ b/drivers/clk/st/clkgen-mux.c > @@ -57,10 +57,17 @@ static void __init st_of_clkgen_mux_setup(struct device_node *np, > const char **parents; > int num_parents = 0; > > + /* > + * First check for reg property within the node to keep backward > + * compatibility, then if reg doesn't exist look at the parent node > + */ > reg = of_iomap(np, 0); > if (!reg) { > - pr_err("%s: Failed to get base address\n", __func__); > - return; > + reg = of_iomap(of_get_parent(np), 0); > + if (!reg) { > + pr_err("%s: Failed to get base address\n", __func__); > + return; > + } > } > > parents = clkgen_mux_get_parents(np, &num_parents); > Reviewed-by: Patrice Chotard <patrice.chotard@xxxxxxxxxxx> Thanks Patrice