On Tue, Nov 9, 2021 at 12:32 PM Robert Marko <robert.marko@xxxxxxxxxx> wrote: > > Add header for the Delta TN48M CPLD provided > resets. > > Signed-off-by: Robert Marko <robert.marko@xxxxxxxxxx> > --- > include/dt-bindings/reset/delta,tn48m-reset.h | 20 +++++++++++++++++++ > 1 file changed, 20 insertions(+) > create mode 100644 include/dt-bindings/reset/delta,tn48m-reset.h > > diff --git a/include/dt-bindings/reset/delta,tn48m-reset.h b/include/dt-bindings/reset/delta,tn48m-reset.h > new file mode 100644 > index 000000000000..d4e9ed12de3e > --- /dev/null > +++ b/include/dt-bindings/reset/delta,tn48m-reset.h > @@ -0,0 +1,20 @@ > +/* SPDX-License-Identifier: GPL-2.0-only */ > +/* > + * Delta TN48M CPLD GPIO driver > + * > + * Copyright (C) 2021 Sartura Ltd. > + * > + * Author: Robert Marko <robert.marko@xxxxxxxxxx> > + */ > + > +#ifndef _DT_BINDINGS_RESET_TN48M_H > +#define _DT_BINDINGS_RESET_TN48M_H > + > +#define CPU_88F7040_RESET 0 > +#define CPU_88F6820_RESET 1 > +#define MAC_98DX3265_RESET 2 > +#define PHY_88E1680_RESET 3 > +#define PHY_88E1512_RESET 4 > +#define POE_RESET 5 > + > +#endif /* _DT_BINDINGS_RESET_TN48M_H */ > -- > 2.33.1 > Does anybody have any comments on the patch as the reset driver got reviewed and the bindings have not? Regards, Robert -- Robert Marko Staff Embedded Linux Engineer Sartura Ltd. Lendavska ulica 16a 10000 Zagreb, Croatia Email: robert.marko@xxxxxxxxxx Web: www.sartura.hr