Not all OPP entries fit into a single word. In particular NVIDIA Tegra OPP tables use multi-word names where first part is freq and second voltage because different hardware versions use different voltages for the same freqs. Allow OPP entry to have multi-worded name separated by hyphen. This silences DT checker warnings about wrong naming scheme. Reviewed-by: David Heidelberg <david@xxxxxxx> Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx> --- Changelog: v3: - Viresh Kumar suggested that we shouldn't support postfix variant. I dropped variant with postfix naming scheme and multi-wording support of table names. v2: - In addition to a multi-wording support, support of the postfix *-opp-table naming scheme is added to the updated pattern. Documentation/devicetree/bindings/opp/opp-v2-base.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/opp/opp-v2-base.yaml b/Documentation/devicetree/bindings/opp/opp-v2-base.yaml index ae3ae4d39843..f79343960539 100644 --- a/Documentation/devicetree/bindings/opp/opp-v2-base.yaml +++ b/Documentation/devicetree/bindings/opp/opp-v2-base.yaml @@ -33,7 +33,7 @@ properties: type: boolean patternProperties: - '^opp-?[0-9]+$': + '^opp(-[0-9]+)*$': type: object description: One or more OPP nodes describing voltage-current-frequency combinations. -- 2.33.1