Am Freitag, 8. Oktober 2021, 03:29:17 CEST schrieb Palmer Dabbelt: > On Thu, 23 Sep 2021 09:59:32 PDT (-0700), robh@xxxxxxxxxx wrote: > > On Mon, 20 Sep 2021 16:49:44 +0200, Krzysztof Kozlowski wrote: > >> The SiFive FU740 Power Reset Clock Interrupt Controller is a reset line > >> provider so add respective reset-cells property to fix: > >> > >> arch/riscv/boot/dts/sifive/hifive-unmatched-a00.dt.yaml: clock-controller@10000000: > >> '#reset-cells' does not match any of the regexes: 'pinctrl-[0-9]+' > >> > >> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxxxxx> > >> --- > >> .../devicetree/bindings/clock/sifive/fu740-prci.yaml | 4 ++++ > >> 1 file changed, 4 insertions(+) > >> > > > > Reviewed-by: Rob Herring <robh@xxxxxxxxxx> > > Acked-by: Palmer Dabbelt <palmerdabbelt@xxxxxxxxxx> > > For some reason I thought these went through your tree, LMK if you were > planning on having me take it through mine. Normally both driver + binding patches go through the driver-tree and actual dts changes through the tree carrying the dts files. So for a clock-patch this should be the clock-tree aka Mike Turquette and Stephen Boyd - already in Cc of original patch, so I'd assume they'll pick it up. Heiko