Device "marvell,armada-3700-uart" should use "marvell,armada-3700-uart-clock" compatible clock. Signed-off-by: Pali Rohár <pali@xxxxxxxxxx> --- Documentation/devicetree/bindings/serial/mvebu-uart.txt | 9 ++++++--- 1 file changed, 6 insertions(+), 3 deletions(-) diff --git a/Documentation/devicetree/bindings/serial/mvebu-uart.txt b/Documentation/devicetree/bindings/serial/mvebu-uart.txt index 2d0dbdf32d1d..a062bbca532c 100644 --- a/Documentation/devicetree/bindings/serial/mvebu-uart.txt +++ b/Documentation/devicetree/bindings/serial/mvebu-uart.txt @@ -14,7 +14,10 @@ Required properties: is provided (possible only with the "marvell,armada-3700-uart" compatible string for backward compatibility), it will only work if the baudrate was initialized by the bootloader and no baudrate - change will then be possible. + change will then be possible. When provided it should be UART1-clk + for standard variant of UART and UART2-clk for extended variant + of UART. TBG clock (with UART TBG divisors d1=d2=1) or xtal clock + should not be used and are supported only for backward compatibility. - interrupts: - Must contain three elements for the standard variant of the IP (marvell,armada-3700-uart): "uart-sum", "uart-tx" and "uart-rx", @@ -34,7 +37,7 @@ Example: uart0: serial@12000 { compatible = "marvell,armada-3700-uart"; reg = <0x12000 0x18>; - clocks = <&xtalclk>; + clocks = <&uartclk 0>; interrupts = <GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>, <GIC_SPI 12 IRQ_TYPE_LEVEL_HIGH>, @@ -45,7 +48,7 @@ Example: uart1: serial@12200 { compatible = "marvell,armada-3700-uart-ext"; reg = <0x12200 0x30>; - clocks = <&xtalclk>; + clocks = <&uartclk 1>; interrupts = <GIC_SPI 30 IRQ_TYPE_EDGE_RISING>, <GIC_SPI 31 IRQ_TYPE_EDGE_RISING>; -- 2.20.1