在 2021-07-22星期四的 10:16 +0200,Maxime Ripard写道: > On Thu, Jul 22, 2021 at 12:55:53AM -0500, Samuel Holland wrote: > > On 7/21/21 9:04 AM, Maxime Ripard wrote: > > > The regulator-ramp-delay property isn't documented in the binding > > > for > > > the AXP806, and it's ignored by the driver. Remove those > > > properties. > > > > This is a generic regulator property, parsed by > > of_get_regulation_constraints, which is called by > > regulator_of_get_init_data in the regulator core. And it appears in > > bindings/regulator/regulator.yaml. I believe the binding needs to be > > fixed, not the device trees. > > It's indeed parsed by the regulator framework, but then it calls into > the driver if that property is set using set_ramp_delay if it's set. Not only is it used for set_ramp_delay, but it's also used to calculate a post-change delay, see the following position (it can be overrided by a custom set_voltage_time in the driver): https://elixir.bootlin.com/linux/latest/source/drivers/regulator/core.c#L3339 > > https://elixir.bootlin.com/linux/latest/source/drivers/regulator/core.c#L1378 > > We don't set that hook for the AXP806 DCDC-A and DCDC-E regulators > (that > use AXP_DESC_RANGES) at all: > > https://elixir.bootlin.com/linux/latest/source/drivers/regulator/axp20x-regulator.c#L343 > > And the only implementation we have (set for AXP_DESC and AXP_DESC_IO) > works only for the AXP209: > > https://elixir.bootlin.com/linux/latest/source/drivers/regulator/axp20x-regulator.c#L368 > > So, it just looks like those properties have never been tested since > they were just ignored. > > Maxime >