The fixed regulator clock name has a unit address, but no reg property, which generates a warning in DTC. Change its name to remove its useless unit address. Signed-off-by: Maxime Ripard <maxime@xxxxxxxxxx> --- arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts b/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts index 7ef96f9ff7ae..6a4af14718f5 100644 --- a/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts +++ b/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts @@ -77,7 +77,7 @@ speaker_amp: audio-amplifier { sound-name-prefix = "Speaker Amp"; }; - vdd_bl: regulator@0 { + vdd_bl: regulator { compatible = "regulator-fixed"; regulator-name = "bl-3v3"; regulator-min-microvolt = <3300000>; -- 2.31.1