BMA253 has two interrupt pins (INT1 and INT2) that can be configured independently. At the moment the bmc150-accel driver does not make use of them but it might be able to in the future, so it's useful to already specify all available interrupts in the device tree. Set maxItems: 2 for interrupts to allow specifying a second one. This is necessary as preparation to move the bosch,bma254 compatible from bosch,bma180.yaml to bosch,bma255.yaml since bma180 allows two interrupts, but BMA254 is better supported by the bmc150-accel driver. Reviewed-by: Linus Walleij <linus.walleij@xxxxxxxxxx> Signed-off-by: Stephan Gerhold <stephan@xxxxxxxxxxx> --- .../devicetree/bindings/iio/accel/bosch,bma255.yaml | 7 ++++++- 1 file changed, 6 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/iio/accel/bosch,bma255.yaml b/Documentation/devicetree/bindings/iio/accel/bosch,bma255.yaml index 8afb0fe8ef5c..65b299a5619b 100644 --- a/Documentation/devicetree/bindings/iio/accel/bosch,bma255.yaml +++ b/Documentation/devicetree/bindings/iio/accel/bosch,bma255.yaml @@ -32,7 +32,12 @@ properties: vddio-supply: true interrupts: - maxItems: 1 + minItems: 1 + maxItems: 2 + description: | + The first interrupt listed must be the one connected to the INT1 pin, + the second (optional) interrupt listed must be the one connected to the + INT2 pin (if available). mount-matrix: description: an optional 3x3 mounting rotation matrix. -- 2.31.1