On Thu, 11 Mar 2021 12:21:41 +0200, Matti Vaittinen wrote: > Support specifying protection/error/warning limits for regulator > over current, over temperature and over/under voltage. > > Most of the PMICs support only "protection" feature but few > setups do also support error/warning level indications. > > On many ICs most of the protection limits can't actually be set. > But for example the ampere limit for over-current protection on ROHM > BD9576 can be configured - or feature can be completely disabled. > > Provide limit setting for all protections/errors for the sake of > the completeness and do that using own properties for all so that > not all users would need to set all levels when only one or few are > supported. > > Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx> > --- > v3: > No changes. > v2: > Shortended property names as suggested by Rob. > > .../bindings/regulator/regulator.yaml | 82 +++++++++++++++++++ > 1 file changed, 82 insertions(+) > Reviewed-by: Rob Herring <robh@xxxxxxxxxx>