Update the default register settings to include the VCO_RESET_CALCODE settings (set by the SiLabs ClockBuilder software but not described in the datasheet). Also update part of the initialization sequence to match ClockBuilder and the datasheet. Fixes: 3044a860fd ("clk: Add Si5341/Si5340 driver") Signed-off-by: Robert Hancock <robert.hancock@xxxxxxxxxx> --- drivers/clk/clk-si5341.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/clk/clk-si5341.c b/drivers/clk/clk-si5341.c index 5221e431f6cb..b758cc9987ca 100644 --- a/drivers/clk/clk-si5341.c +++ b/drivers/clk/clk-si5341.c @@ -350,6 +350,8 @@ static const struct si5341_reg_default si5341_reg_defaults[] = { { 0x094A, 0x00 }, /* INx_TO_PFD_EN (disabled) */ { 0x0A02, 0x00 }, /* Not in datasheet */ { 0x0B44, 0x0F }, /* PDIV_ENB (datasheet does not mention what it is) */ + { 0x0B57, 0x10 }, /* VCO_RESET_CALCODE (not described in datasheet) */ + { 0x0B58, 0x05 }, /* VCO_RESET_CALCODE (not described in datasheet) */ }; /* Read and interpret a 44-bit followed by a 32-bit value in the regmap */ @@ -1104,7 +1106,7 @@ static const struct si5341_reg_default si5341_preamble[] = { { 0x0B25, 0x00 }, { 0x0502, 0x01 }, { 0x0505, 0x03 }, - { 0x0957, 0x1F }, + { 0x0957, 0x17 }, { 0x0B4E, 0x1A }, }; -- 2.27.0