On 30.08.2020 15:51, Krzysztof Kozlowski wrote: > The S3C RTC requires 32768 Hz clock as input which is provided by PMIC > (Maxim MAX8997). However there is no clock provided for the PMIC and > the driver registers the clock as regulator. This is an old driver > which will not be updated so add a workaround: > 1. Enable the "clock" regulator in PMIC, > 2. Add a fixed-clock to fill missing clock phandle reference in S3C RTC. > > This allows to enable the S3C RTC and fixes dtbs_check warnings: > > arch/arm/boot/dts/exynos4210-origen.dt.yaml: rtc@10070000: clocks: [[5, 346]] is too short > arch/arm/boot/dts/exynos4210-origen.dt.yaml: rtc@10070000: clock-names: ['rtc'] is too short > > Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> Confirmed, this workaround enables s3c-rtc driver operation on this board. Tested-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx> > --- > arch/arm/boot/dts/exynos4210-origen.dts | 14 ++++++++++++++ > 1 file changed, 14 insertions(+) > > diff --git a/arch/arm/boot/dts/exynos4210-origen.dts b/arch/arm/boot/dts/exynos4210-origen.dts > index 890525b10d22..747221bbb856 100644 > --- a/arch/arm/boot/dts/exynos4210-origen.dts > +++ b/arch/arm/boot/dts/exynos4210-origen.dts > @@ -100,6 +100,13 @@ > compatible = "samsung,clock-xusbxti"; > clock-frequency = <24000000>; > }; > + > + pmic_ap_clk: pmic-ap-clk { > + /* Workaround for missing clock on max8997 PMIC */ > + compatible = "fixed-clock"; > + #clock-cells = <0>; > + clock-frequency = <32768>; > + }; > }; > > display-timings { > @@ -286,6 +293,11 @@ > regulator-boot-on; > regulator-always-on; > }; > + > + EN32KHZ_AP { > + regulator-name = "EN32KHZ_AP"; > + regulator-always-on; > + }; > }; > }; > }; > @@ -331,6 +343,8 @@ > > &rtc { > status = "okay"; > + clocks = <&clock CLK_RTC>, <&pmic_ap_clk>; > + clock-names = "rtc", "rtc_src"; > }; > > &tmu { Best regards -- Marek Szyprowski, PhD Samsung R&D Institute Poland