Commit 52005dece527 ("ARM: dts: Add assigned clock parents to CMU node for exynos3250") added assigned clocks under Clock Management Unit to fix hangs when accessing ISP registers. This is not the place for it as CMU does not have a required "clocks" property: arch/arm/boot/dts/exynos3250-artik5-eval.dt.yaml: clock-controller@10030000: 'clocks' is a dependency of 'assigned-clocks' Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> --- Not tested and I wonder whether actually correct. For example, what will happen if devfreq (exynos-bus) is not built in? Could someone verify it? --- arch/arm/boot/dts/exynos3250.dtsi | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/arch/arm/boot/dts/exynos3250.dtsi b/arch/arm/boot/dts/exynos3250.dtsi index c67c70e46794..6d467022d929 100644 --- a/arch/arm/boot/dts/exynos3250.dtsi +++ b/arch/arm/boot/dts/exynos3250.dtsi @@ -214,10 +214,6 @@ compatible = "samsung,exynos3250-cmu"; reg = <0x10030000 0x20000>; #clock-cells = <1>; - assigned-clocks = <&cmu CLK_MOUT_ACLK_400_MCUISP_SUB>, - <&cmu CLK_MOUT_ACLK_266_SUB>; - assigned-clock-parents = <&cmu CLK_FIN_PLL>, - <&cmu CLK_FIN_PLL>; }; cmu_dmc: clock-controller@105c0000 { @@ -835,6 +831,8 @@ compatible = "samsung,exynos-bus"; clocks = <&cmu CLK_DIV_ACLK_400_MCUISP>; clock-names = "bus"; + assigned-clocks = <&cmu CLK_MOUT_ACLK_400_MCUISP_SUB>; + assigned-clock-parents = <&cmu CLK_FIN_PLL>; operating-points-v2 = <&bus_mcuisp_opp_table>; status = "disabled"; }; @@ -843,6 +841,8 @@ compatible = "samsung,exynos-bus"; clocks = <&cmu CLK_DIV_ACLK_266>; clock-names = "bus"; + assigned-clocks = <&cmu CLK_MOUT_ACLK_266_SUB>; + assigned-clock-parents = <&cmu CLK_FIN_PLL>; operating-points-v2 = <&bus_isp_opp_table>; status = "disabled"; }; -- 2.17.1