On 8/28/20 6:05 AM, Andre Przywara wrote: > The SP805 binding sets the name for the actual watchdog clock to > "wdog_clk" (with an underscore). > > Change the name in the DTs for Broadcom platforms to match that. The > Linux and U-Boot driver use the *first* clock for this purpose anyway, > so it does not break anything. Not that it really matters because the driver does a devm_clk_get(&adev->dev, NULL), but yes, this should be fixed to conform to the binding. > > Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx> Acked-by: Florian Fainelli <f.fainelli@xxxxxxxxx> -- Florian