The DT binding for SP804 requires to have an "arm,primecell" compatible string. Add this string so that the Linux primecell bus driver picks the device up and activates the clock. Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx> --- arch/arm/boot/dts/bcm-nsp.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm/boot/dts/bcm-nsp.dtsi b/arch/arm/boot/dts/bcm-nsp.dtsi index 0346ea621f0f..1333ef8be0a2 100644 --- a/arch/arm/boot/dts/bcm-nsp.dtsi +++ b/arch/arm/boot/dts/bcm-nsp.dtsi @@ -368,7 +368,7 @@ }; ccbtimer0: timer@34000 { - compatible = "arm,sp804"; + compatible = "arm,sp804", "arm,primecell"; reg = <0x34000 0x1000>; interrupts = <GIC_SPI 90 IRQ_TYPE_LEVEL_HIGH>, <GIC_SPI 91 IRQ_TYPE_LEVEL_HIGH>; -- 2.17.1