This converts the DT binding documentation for the ARM SP-804 timer IP over to json-schema. Most properties are just carried over, the clocks property requirement (either one or three clocks) is now formalised and enforced. As the former binding didn't specify clock-names, and there is no common name used by the existing DTs, I refrained from adding them. The requirement for the APB clock is enforced by the primecell binding already. Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx> --- .../devicetree/bindings/timer/arm,sp804.txt | 29 ------- .../devicetree/bindings/timer/arm,sp804.yaml | 82 +++++++++++++++++++ 2 files changed, 82 insertions(+), 29 deletions(-) delete mode 100644 Documentation/devicetree/bindings/timer/arm,sp804.txt create mode 100644 Documentation/devicetree/bindings/timer/arm,sp804.yaml diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.txt b/Documentation/devicetree/bindings/timer/arm,sp804.txt deleted file mode 100644 index 5cd8eee74af1..000000000000 --- a/Documentation/devicetree/bindings/timer/arm,sp804.txt +++ /dev/null @@ -1,29 +0,0 @@ -ARM sp804 Dual Timers ---------------------------------------- - -Required properties: -- compatible: Should be "arm,sp804" & "arm,primecell" -- interrupts: Should contain the list of Dual Timer interrupts. This is the - interrupt for timer 1 and timer 2. In the case of a single entry, it is - the combined interrupt or if "arm,sp804-has-irq" is present that - specifies which timer interrupt is connected. -- reg: Should contain location and length for dual timer register. -- clocks: clocks driving the dual timer hardware. This list should be 1 or 3 - clocks. With 3 clocks, the order is timer0 clock, timer1 clock, - apb_pclk. A single clock can also be specified if the same clock is - used for all clock inputs. - -Optional properties: -- arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this - specifies if the irq connection is for timer 1 or timer 2. A value of 1 - or 2 should be used. - -Example: - - timer0: timer@fc800000 { - compatible = "arm,sp804", "arm,primecell"; - reg = <0xfc800000 0x1000>; - interrupts = <0 0 4>, <0 1 4>; - clocks = <&timclk1 &timclk2 &pclk>; - clock-names = "timer1", "timer2", "apb_pclk"; - }; diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.yaml b/Documentation/devicetree/bindings/timer/arm,sp804.yaml new file mode 100644 index 000000000000..77d35bc41176 --- /dev/null +++ b/Documentation/devicetree/bindings/timer/arm,sp804.yaml @@ -0,0 +1,82 @@ +# SPDX-License-Identifier: GPL-2.0 +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/timer/arm,sp804.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: ARM sp804 Dual Timers + +maintainers: + - Haojian Zhuang <haojian.zhuang@xxxxxxxxxx> + +description: |+ + The Arm SP804 IP implements two independent timers, configurable for + 16 or 32 bit operation and capable of running in one-shot, periodic, or + free-running mode. The input clock is shared, but can be gated and prescaled + independently for each timer. + +# Need a custom select here or 'arm,primecell' will match on lots of nodes +select: + properties: + compatible: + contains: + const: arm,sp804 + required: + - compatible + +properties: + compatible: + items: + - const: arm,sp804 + - const: arm,primecell + + interrupts: + description: | + If two interrupts are listed, those are the interrupts for timer + 1 and 2, respectively. If there is only a single interrupt, it is + either a combined interrupt or the sole interrupt of one timer, as + specified by the "arm,sp804-has-irq" property. + minItems: 1 + maxItems: 2 + + reg: + description: The physical base address of the SP804 IP. + maxItems: 1 + + clocks: + description: | + Clocks driving the dual timer hardware. This list should + be 1 or 3 clocks. With 3 clocks, the order is timer0 clock, timer1 + clock, apb_pclk. A single clock can also be specified if the same + clock is used for all clock inputs. + oneOf: + - items: + - description: clock for timer 1 + - description: clock for timer 2 + - description: bus clock + - items: + - description: unified clock for both timers and the bus + + arm,sp804-has-irq: + description: If only one interrupt line is connected to the interrupt + controller, this property specifies which timer is connected to this + line. + $ref: /schemas/types.yaml#/definitions/uint32 + minimum: 1 + maximum: 2 + +required: + - compatible + - interrupts + - reg + - clocks + +examples: + - | + timer0: timer@fc800000 { + compatible = "arm,sp804", "arm,primecell"; + reg = <0xfc800000 0x1000>; + interrupts = <0 0 4>, <0 1 4>; + clocks = <&timclk1>, <&timclk2>, <&pclk>; + clock-names = "timer1", "timer2", "apb_pclk"; + }; -- 2.17.1