Re: [EXTERNAL] Re: [PATCH v17 2/4] dt-bindings: power: Convert battery.txt to battery.yaml

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 7/26/20 6:24 PM, Sebastian Reichel wrote:
Hi,

On Mon, Jul 20, 2020 at 03:43:58PM -0500, Ricardo Rivera-Matos wrote:
From: Dan Murphy <dmurphy@xxxxxx>

Convert the battery.txt file to yaml and fix up the examples.
The examples were correct for the existing binding. What you did
is completly changing the binding description (without modifying
the code) resulting in examples and any existing users being
incorrect and code not matching up with the binding.
ACK

Signed-off-by: Dan Murphy <dmurphy@xxxxxx>
---
  .../bindings/power/supply/battery.txt         |  86 +---------
  .../bindings/power/supply/battery.yaml        | 157 ++++++++++++++++++
  2 files changed, 158 insertions(+), 85 deletions(-)
  create mode 100644 Documentation/devicetree/bindings/power/supply/battery.yaml

diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt
index 5e29595edd74..a9f80cc49068 100644
--- a/Documentation/devicetree/bindings/power/supply/battery.txt
+++ b/Documentation/devicetree/bindings/power/supply/battery.txt
@@ -1,87 +1,3 @@
-Battery Characteristics
-
-The devicetree battery node provides static battery characteristics.
-In smart batteries, these are typically stored in non-volatile memory
-on a fuel gauge chip. The battery node should be used where there is
-no appropriate non-volatile memory, or it is unprogrammed/incorrect.
-
-Upstream dts files should not include battery nodes, unless the battery
-represented cannot easily be replaced in the system by one of a
-different type. This prevents unpredictable, potentially harmful,
-behavior should a replacement that changes the battery type occur
-without a corresponding update to the dtb.
+The contents of this file has been moved to battery.yaml
Please note that not all charger drivers respect all of the properties.
-
-Required Properties:
- - compatible: Must be "simple-battery"
-
-Optional Properties:
- - over-voltage-threshold-microvolt: battery over-voltage limit
- - re-charge-voltage-microvolt: limit to automatically start charging again
- - voltage-min-design-microvolt: drained battery voltage
- - voltage-max-design-microvolt: fully charged battery voltage
- - energy-full-design-microwatt-hours: battery design energy
- - charge-full-design-microamp-hours: battery design capacity
- - trickle-charge-current-microamp: current for trickle-charge phase
- - precharge-current-microamp: current for pre-charge phase
- - precharge-upper-limit-microvolt: limit when to change to constant charging
- - charge-term-current-microamp: current for charge termination phase
- - constant-charge-current-max-microamp: maximum constant input current
- - constant-charge-voltage-max-microvolt: maximum constant input voltage
- - factory-internal-resistance-micro-ohms: battery factory internal resistance
- - ocv-capacity-table-0: An array providing the open circuit voltage (OCV)
-   of the battery and corresponding battery capacity percent, which is used
-   to look up battery capacity according to current OCV value. And the open
-   circuit voltage unit is microvolt.
- - ocv-capacity-table-1: Same as ocv-capacity-table-0
- ......
- - ocv-capacity-table-n: Same as ocv-capacity-table-0
- - ocv-capacity-celsius: An array containing the temperature in degree Celsius,
-   for each of the battery capacity lookup table. The first temperature value
-   specifies the OCV table 0, and the second temperature value specifies the
-   OCV table 1, and so on.
- - resistance-temp-table: An array providing the temperature in degree Celsius
-   and corresponding battery internal resistance percent, which is used to look
-   up the resistance percent according to current temperature to get a accurate
-   batterty internal resistance in different temperatures.
-
-Battery properties are named, where possible, for the corresponding
-elements in enum power_supply_property, defined in
-https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h
-
-Batteries must be referenced by chargers and/or fuel-gauges
-using a phandle. The phandle's property should be named
-"monitored-battery".
-
-Example:
-
-	bat: battery {
-		compatible = "simple-battery";
-		voltage-min-design-microvolt = <3200000>;
-		voltage-max-design-microvolt = <4200000>;
-		energy-full-design-microwatt-hours = <5290000>;
-		charge-full-design-microamp-hours = <1430000>;
-		precharge-current-microamp = <256000>;
-		charge-term-current-microamp = <128000>;
-		constant-charge-current-max-microamp = <900000>;
-		constant-charge-voltage-max-microvolt = <4200000>;
-		factory-internal-resistance-micro-ohms = <250000>;
-		ocv-capacity-celsius = <(-10) 0 10>;
-		ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
-		ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
-		ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
-		resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
-	};
-
-	charger: charger@11 {
-		....
-		monitored-battery = <&bat>;
-		...
-	};
-
-	fuel_gauge: fuel-gauge@22 {
-		....
-		monitored-battery = <&bat>;
-		...
-	};
diff --git a/Documentation/devicetree/bindings/power/supply/battery.yaml b/Documentation/devicetree/bindings/power/supply/battery.yaml
new file mode 100644
index 000000000000..d7a2380b46f9
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/battery.yaml
@@ -0,0 +1,157 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/power/supply/battery.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Battery Characteristics
+
+maintainers:
+  - Sebastian Reichel <sre@xxxxxxxxxx>
+
+description: |
+  The devicetree battery node provides static battery characteristics.
+  In smart batteries, these are typically stored in non-volatile memory
+  on a fuel gauge chip. The battery node should be used where there is
+  no appropriate non-volatile memory, or it is unprogrammed/incorrect.
+
+  Upstream dts files should not include battery nodes, unless the battery
+  represented cannot easily be replaced in the system by one of a
+  different type. This prevents unpredictable, potentially harmful,
+  behavior should a replacement that changes the battery type occur
+  without a corresponding update to the dtb.
+
+  Battery properties are named, where possible, for the corresponding elements
+  in enum power_supply_property, defined in include/linux/power_supply.h
+
+  Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
+  The phandle's property should be named "monitored-battery".
+
+properties:
+  compatible:
+    const: simple-battery
+
+  over-voltage-threshold-microvolt:
+    description: battery over-voltage limit
+
+  re-charge-voltage-microvolt:
+    description: limit to automatically start charging again
+
+  voltage-min-design-microvolt:
+    description: drained battery voltage
+
+  voltage-max-design-microvolt:
+    description: fully charged battery voltage
+
+  energy-full-design-microwatt-hours:
+    description: battery design energy
+
+  charge-full-design-microamp-hours:
+    description: battery design capacity
+
+  trickle-charge-current-microamp:
+    description: current for trickle-charge phase
+
+  precharge-current-microamp:
+    description: current for pre-charge phase
+
+  precharge-upper-limit-microvolt:
+    description: limit when to change to constant charging
+
+  charge-term-current-microamp:
+    description: current for charge termination phase
+
+  constant-charge-current-max-microamp:
+    description: maximum constant input current
+
+  constant-charge-voltage-max-microvolt:
+    description: maximum constant input voltage
+
+  factory-internal-resistance-micro-ohms:
+    description: battery factory internal resistance
+
+  monitored-battery:
+    $ref: /schemas/types.yaml#/definitions/phandle
+    description: phandle to the battery node being monitored
monitored-battery is not a valid property of simple-battery node
(the one having compatible = "simple-battery"). It needs to be
listed in the binding _using_ simple-battery (which you did in
the bq2515x binding). Drop it.
ACK

+required:
+  - compatible
+
+patternProperties:
+  '^ocv-capacity-table-[0-100]$':
+    $ref: /schemas/types.yaml#/definitions/uint32-matrix
+    description: |
+      An array providing the open circuit voltage (OCV)
+      of the battery and corresponding battery capacity percent, which is used
+      to look up battery capacity according to current OCV value. And the open
+      circuit voltage unit is microvolt.
+    maxItems: 100
+    items:
+      items:
+        - description: open circuit voltage (OCV) in microvolts
+        - description: battery capacity percent
+          maximum: 100
This looks ok.
Sounds good

+  '^resistance-temp-table-[0-100]$':
+    $ref: /schemas/types.yaml#/definitions/uint32-matrix
+    description: |
+      An array providing the temperature in degree Celsius
+      and corresponding battery internal resistance percent, which is used to
+      look up the resistance percent according to current temperature to get an
+      accurate batterty internal resistance in different temperatures.
+    maxItems: 100
+    items:
+      items:
+        - description: internal resistance percent
+        - description: battery capacity percent
+          maximum: 100
This is a single property ("resistance-temp-table") describing
a graph with temperature on one axis and battery internal resistance
on the other axis. The first cell is temperature in degree Celsius
and the second cell is internal resistance percentage. So old
example

resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;

translates into

20° => 100% of "factory-internal-resistance-micro-ohms"
10° => 90% of "factory-internal-resistance-micro-ohms"
Okay thanks for explaining this.

+  '^ocv-capacity-celsius-[0-100]$':
+    $ref: /schemas/types.yaml#/definitions/uint32-matrix
+    description: |
+      An array containing the temperature in degree Celsius,
+      for each of the battery capacity lookup table.
+    maxItems: 100
+    items:
+      items:
+        - description: temperature in degree Celsius
+        - description: battery capacity percent
+          maximum: 100
This is also incorrect. This is a single property ("ocv-capacity-celsius"),
which is the lookup table for "^ocv-capacity-table-[0-100]$". It maps
ocv-capacity tables to temperatures. Let me use the example from the
old *.txt binding again:

ocv-capacity-celsius = <(-10) 0 10>;
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;

-10 degree Celsius is index 0, so ocv-capacity-table-0 should be
used for -10 degrees Celsius.

0 degrees Celsius is index 1, so ocv-capacity-table-1 should
be used for this temperature.

10 degrees Celsius is index 2, so ocv-capacity-table-2
should be used for this temperature.
ACK

-- Sebastian

+additionalProperties: false
+
+examples:
+  - |
+    power {
+      #address-cells = <1>;
+      #size-cells = <0>;
+
+      battery: battery {
+        compatible = "simple-battery";
+        over-voltage-threshold-microvolt = <4500000>;
+        re-charge-voltage-microvolt = <250000>;
+        voltage-min-design-microvolt = <3200000>;
+        voltage-max-design-microvolt = <4200000>;
+        energy-full-design-microwatt-hours = <5290000>;
+        charge-full-design-microamp-hours = <1430000>;
+        precharge-current-microamp = <256000>;
+        precharge-upper-limit-microvolt = <2500000>;
+        charge-term-current-microamp = <128000>;
+        constant-charge-current-max-microamp = <900000>;
+        constant-charge-voltage-max-microvolt = <4200000>;
+        factory-internal-resistance-micro-ohms = <250000>;
+        ocv-capacity-celsius-0 = <(-10) 10>;
+        ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
+        resistance-temp-table-0 = <20 100>, <10 90>, <0 80>, <(-10) 60>;
+      };
+
+      charger@11 {
+        reg = <0x11>;
+        monitored-battery = <&battery>;
+      };
+
+      fuel-gauge@22 {
+        reg = <0x22>;
+        monitored-battery = <&battery>;
+      };
+    };
--
2.27.0