> On 21 Jul 2020, at 2:24 am, Kevin Hilman <khilman@xxxxxxxxxxxx> wrote: > > Christian Hewitt <christianshewitt@xxxxxxxxx> writes: > >> Similar to other G12B devices using the W400 dtsi, I see reports of mmc0 >> tuning errors on VIM3 after a few hours uptime: >> >> [12483.917391] mmc0: tuning execution failed: -5 >> [30535.551221] mmc0: tuning execution failed: -5 >> [35359.953671] mmc0: tuning execution failed: -5 >> [35561.875332] mmc0: tuning execution failed: -5 >> [61733.348709] mmc0: tuning execution failed: -5 >> >> I do not see the same on VIM3L, so remove sd-uhs-sdr50 from the common dtsi >> to silence the error, then (re)add it to the VIM3L dts. >> >> Signed-off-by: Chrisitan Hewitt <christianshewitt@xxxxxxxxx> > > Fixes? > > Kevin I’ll resend v2 with the fixes tag(s). Thanks. Christian