14.07.2020 02:46, Rob Herring пишет: > On Sun, Jun 07, 2020 at 05:41:06PM +0300, Dmitry Osipenko wrote: >> Document generic battery temperature properties. >> >> Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx> >> --- >> .../devicetree/bindings/power/supply/battery.txt | 10 ++++++++++ >> 1 file changed, 10 insertions(+) > > This is close to being converted to schema: > > https://lore.kernel.org/linux-pm/20200707212914.31540-1-r-rivera-matos@xxxxxx/ Thanks! I'll keep an eye on this patch. >> diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt >> index 5e29595edd74..e0c35eff9d3f 100644 >> --- a/Documentation/devicetree/bindings/power/supply/battery.txt >> +++ b/Documentation/devicetree/bindings/power/supply/battery.txt >> @@ -45,6 +45,16 @@ Optional Properties: >> and corresponding battery internal resistance percent, which is used to look >> up the resistance percent according to current temperature to get a accurate >> batterty internal resistance in different temperatures. >> + - temperature-ambient-min-alert-celsius: Alert when ambient temperature of a >> + battery is lower than threshold value. >> + - temperature-ambient-max-alert-celsius: Alert when ambient temperature of a >> + battery is higher than threshold value. >> + - temperature-min-alert-celsius: Alert when battery temperature is lower >> + than threshold value. >> + - temperature-max-alert-celsius: Alert when battery temperature is higher >> + than threshold value. >> + - temperature-min-celsius: minimum temperature at which battery can operate >> + - temperature-max-celsius: maximum temperature at which battery can operate > > Perhaps 'temperature' is redundant since we have units. > > Perhaps do <min max> properties given specifying only min or max is > probably not valid? Thank you for the suggestions, I'll consider them for the v3!