On Fri, Jun 26, 2020 at 07:15:41PM +0530, Manivannan Sadhasivam wrote: > On Wed, Jun 24, 2020 at 08:47:52PM +0300, Cristian Ciocaltea wrote: > > The h_clk clock in the Actions Semi S500 SoC clock driver has an > > invalid parent. Replace with the correct one. > > > > Signed-off-by: Cristian Ciocaltea <cristian.ciocaltea@xxxxxxxxx> > > Reviewed-by: Manivannan Sadhasivam <manivannan.sadhasivam@xxxxxxxxxx> > > You should add fixes tag for this patch and it needs to be backported as well. > > Thanks, > Mani Right, I added the tag: Fixes: ed6b4795ece4 ("clk: actions: Add clock driver for S500 SoC") Thanks, Cristi > > > --- > > drivers/clk/actions/owl-s500.c | 2 +- > > 1 file changed, 1 insertion(+), 1 deletion(-) > > > > diff --git a/drivers/clk/actions/owl-s500.c b/drivers/clk/actions/owl-s500.c > > index e2007ac4d235..0eb83a0b70bc 100644 > > --- a/drivers/clk/actions/owl-s500.c > > +++ b/drivers/clk/actions/owl-s500.c > > @@ -183,7 +183,7 @@ static OWL_GATE(timer_clk, "timer_clk", "hosc", CMU_DEVCLKEN1, 27, 0, 0); > > static OWL_GATE(hdmi_clk, "hdmi_clk", "hosc", CMU_DEVCLKEN1, 3, 0, 0); > > > > /* divider clocks */ > > -static OWL_DIVIDER(h_clk, "h_clk", "ahbprevdiv_clk", CMU_BUSCLK1, 12, 2, NULL, 0, 0); > > +static OWL_DIVIDER(h_clk, "h_clk", "ahbprediv_clk", CMU_BUSCLK1, 12, 2, NULL, 0, 0); > > static OWL_DIVIDER(rmii_ref_clk, "rmii_ref_clk", "ethernet_pll_clk", CMU_ETHERNETPLL, 1, 1, rmii_ref_div_table, 0, 0); > > > > /* factor clocks */ > > -- > > 2.27.0 > >