On 26 May 2014 21:27, Lucas Stach <l.stach@xxxxxxxxxxxxxx> wrote: > No, we need the regulator to determine which OPPs are actually useable. > If the regulator is only supplying 1.1V we can only scale to 800MHz max, > which is the case for some of the industrial i.MX53 versions. Go and add another binding for this max-volt.. And lets see how others respond. You can give a link to this discussion as others might find this very helpful. -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html