On Sat, Mar 28, 2020 at 7:50 PM Fabio Estevam <festevam@xxxxxxxxx> wrote: > The following warnings are seen with 'make dt_binding_check': > > Documentation/devicetree/bindings/clock/arm,syscon-icst.example.dts:17.16-24.11: Warning (unit_address_vs_reg): /example-0/clock@00: node has a unit name, but no reg or ranges property > Documentation/devicetree/bindings/clock/arm,syscon-icst.example.dts:17.16-24.11: Warning (unit_address_format): /example-0/clock@00: unit name should not have leading 0s > > Fix them by removing the unneeded clock unit name. > > Signed-off-by: Fabio Estevam <festevam@xxxxxxxxx> Reviewed-by: Linus Walleij <linus.walleij@xxxxxxxxxx> Yours, Linus Walleij