[PATCH v3 0/3] Add Reset and Wakeup support for CCS811

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Manivannan Sadhasivam <mani@xxxxxxxxxx>

Hello,

This patchset adds external reset and wakeup support for CCS811 VOC
gas sensor. The nRESET and nWAKE pins available on the device are
utilised to provide these functionalities.

The patchset has been validated using CCS811 connected to STM32MP1 based
board over I2C.

While at it, the devicetree yaml binding and OF match table for this sensor
are also added.

Thanks,
Mani

Changes in v3:

* Added ccs811_set_wake(false) to all error paths before calling it actually
* Added Andy's reviewed-by tag
* Added comment for reset procedure and dropped error print for gpio request

Changes in v2:

* Fixed DT binding schema and switched to dual license (GPL/BSD)
* Returned actual error code from devm_gpiod_get_optional()
* Dropped of.h include and of_match_ptr()

Manivannan Sadhasivam (3):
  iio: chemical: Add support for external Reset and Wakeup in CCS811
  iio: chemical: Add OF match table for CCS811 VOC sensor
  dt-bindings: serial: Add binding for software flow control in STM32
    UART

 .../bindings/serial/st,stm32-uart.yaml        |  15 ++-
 drivers/iio/chemical/ccs811.c                 | 112 ++++++++++++++++--
 2 files changed, 115 insertions(+), 12 deletions(-)

-- 
2.17.1




[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]


  Powered by Linux