On Fri, Apr 3, 2020 at 9:04 AM Anson Huang <anson.huang@xxxxxxx> wrote: > > Hi, Amit > > > Subject: Re: [PATCH V3 3/3] arm64: dts: imx8mp: Add thermal zones support > > > > On Mon, Mar 23, 2020 at 6:05 PM Anson Huang <Anson.Huang@xxxxxxx> > > wrote: > > > > > > i.MX8MP has a TMU inside which supports two thermal zones, add support > > > for them. > > > > > > Signed-off-by: Anson Huang <Anson.Huang@xxxxxxx> > > > > > > [snip] > > > > > > > > + thermal-zones { > > > + cpu-thermal { > > > + polling-delay-passive = <250>; > > > + polling-delay = <2000>; > > > + thermal-sensors = <&tmu 0x0>; > > > > No need for 0x0, just use 0 > > OK. > > > > > > + trips { > > > + cpu_alert0: trip0 { > > > + temperature = <85000>; > > > + hysteresis = <2000>; > > > + type = "passive"; > > > + }; > > > + > > > + cpu_crit0: trip1 { > > > + temperature = <95000>; > > > + hysteresis = <2000>; > > > + type = "critical"; > > > + }; > > > + }; > > > + > > > + cooling-maps { > > > + map0 { > > > + trip = <&cpu_alert0>; > > > + cooling-device = > > > + <&A53_0 > > THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > > > + <&A53_1 > > THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > > > + <&A53_2 > > THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, > > > + <&A53_3 > > THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; > > > + }; > > > + }; > > > + }; > > > + > > > + soc-thermal { > > > + polling-delay-passive = <250>; > > > + polling-delay = <2000>; > > > + thermal-sensors = <&tmu 0x1>; > > > > No need for 0x1, just use 1 > > OK. > > > > > > + trips { > > > + soc_alert0: trip0 { > > > + temperature = <85000>; > > > + hysteresis = <2000>; > > > + type = "passive"; > > > + }; > > > + > > > + soc_crit0: trip1 { > > > + temperature = <95000>; > > > + hysteresis = <2000>; > > > + type = "critical"; > > > + }; > > > + }; > > > > You need a cooling-map here since you have a passive trip point. > > Currently, there is no cooling map defined for soc thermal zone, the cpufreq cooling > is mapped to cpu thermal zone already, so do you think it is OK to leave it as no cooling > map, or it is better to put cpufreq cooling for soc thermal zone as well? > If there is no cooling, why do you need a passive trip point? Just make it a hot trip that will send you a nofication (if .notify callback registered). Regards, Amit