We added coulomb counter calibration support With commit 0cb90f071f73 ("power: supply: cpcap-battery: Add basic coulomb counter calibrate support"), but we also need to configure the related interrupt. Without the interrupt calibration happens based on a timeout after two seconds, with the interrupt the calibration just gets done a bit faster. Cc: Merlijn Wajer <merlijn@xxxxxxxxxx> Cc: Pavel Machek <pavel@xxxxxx> Signed-off-by: Tony Lindgren <tony@xxxxxxxxxxx> --- arch/arm/boot/dts/motorola-cpcap-mapphone.dtsi | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-) diff --git a/arch/arm/boot/dts/motorola-cpcap-mapphone.dtsi b/arch/arm/boot/dts/motorola-cpcap-mapphone.dtsi --- a/arch/arm/boot/dts/motorola-cpcap-mapphone.dtsi +++ b/arch/arm/boot/dts/motorola-cpcap-mapphone.dtsi @@ -27,11 +27,12 @@ compatible = "motorola,cpcap-battery"; interrupts-extended = < &cpcap 6 0 &cpcap 5 0 &cpcap 3 0 - &cpcap 20 0 &cpcap 54 0 + &cpcap 20 0 &cpcap 54 0 &cpcap 57 0 >; interrupt-names = "eol", "lowbph", "lowbpl", - "chrgcurr1", "battdetb"; + "chrgcurr1", "battdetb", + "cccal"; io-channels = <&cpcap_adc 0 &cpcap_adc 1 &cpcap_adc 5 &cpcap_adc 6>; io-channel-names = "battdetb", "battp", -- 2.24.1