On 1/8/2020 1:25 AM, Philipp Zabel wrote: > Hi Florian, > > On Tue, 2020-01-07 at 10:30 -0800, Florian Fainelli wrote: >> Hi Jens, Philipp, >> >> These three patches are a follow-up to my previous series titled: ata: >> ahci_brcm: Fixes and new device support. >> >> After submitting the BCM7216 RESCAL reset driver, Philipp the reset >> controller maintained indicated that the reset line should be self >> de-asserting and so reset_control_reset() should be used instead. >> >> These three patches update the driver in that regard. It would be great if >> you could apply those and get them queued up for 5.6 since they are >> directly related to the previous series. >> >> Changes in v3: >> - introduced a preliminary patch making use of the proper reset control >> API in order to manage the optional reset controller line >> - updated patches after introducing that preliminary patch > > The third patch could be simplified by storing the rescal reset control > in a separate struct member and relying on the optional reset control > API more. This is just a suggestion though, the series looks fine as-is. > > Reviewed-by: Philipp Zabel <p.zabel@xxxxxxxxxxxxxx> Thanks! Jens is that good for you? -- Florian