Documentation of max17040 based fuel gauge characteristics. For configure low level state of charge threshold alert signaled from max17043/max17044 we add "maxim,alert-low-soc-level" property. Signed-off-by: Matheus Castello <matheus@xxxxxxxxxxxxxxx> Reviewed-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx> Reviewed-by: Rob Herring <robh@xxxxxxxxxx> --- .../power/supply/max17040_battery.txt | 33 +++++++++++++++++++ 1 file changed, 33 insertions(+) create mode 100644 Documentation/devicetree/bindings/power/supply/max17040_battery.txt diff --git a/Documentation/devicetree/bindings/power/supply/max17040_battery.txt b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt new file mode 100644 index 000000000000..f2d0b22b5f79 --- /dev/null +++ b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt @@ -0,0 +1,33 @@ +max17040_battery +~~~~~~~~~~~~~~~~ + +Required properties : + - compatible : "maxim,max17040" or "maxim,max77836-battery" + - reg: i2c slave address + +Optional properties : +- maxim,alert-low-soc-level : The alert threshold that sets the state of + charge level (%) where an interrupt is + generated. Can be configured from 1 up to 32 + (%). If skipped the power up default value of + 4 (%) will be used. +- interrupts : Interrupt line see Documentation/devicetree/ + bindings/interrupt-controller/interrupts.txt +- wakeup-source : This device has wakeup capabilities. Use this + property to use alert low SOC level interrupt + as wake up source. + +Optional properties support interrupt functionality for alert low state of +charge level, present in some ICs in the same family, and should be used with +compatible "maxim,max77836-battery". + +Example: + + battery-fuel-gauge@36 { + compatible = "maxim,max77836-battery"; + reg = <0x36>; + maxim,alert-low-soc-level = <10>; + interrupt-parent = <&gpio7>; + interrupts = <2 IRQ_TYPE_EDGE_FALLING>; + wakeup-source; + }; -- 2.24.0.rc2