śr., 16 paź 2019 o 09:51 Bibby Hsieh <bibby.hsieh@xxxxxxxxxxxx> napisał(a): > > Although in the most platforms, the power of eeprom and i2c > are alway on, some platforms disable the eeprom and i2c power > in order to meet low power request. > This patch add the pm_runtime ops to control power to support > all platforms. > > Changes since v2: > - rebase onto v5.4-rc1 > - add pm_runtime_disable and regulator_bulk_disable at > err return in probe function > > Changes since v1: > - remove redundant code > - fixup coding style > > Signed-off-by: Bibby Hsieh <bibby.hsieh@xxxxxxxxxxxx> > --- > drivers/misc/eeprom/at24.c | 63 +++++++++++++++++++++++++++++++++++++- > 1 file changed, 62 insertions(+), 1 deletion(-) > > diff --git a/drivers/misc/eeprom/at24.c b/drivers/misc/eeprom/at24.c > index 2cccd82a3106..7ff614aef301 100644 > --- a/drivers/misc/eeprom/at24.c > +++ b/drivers/misc/eeprom/at24.c > @@ -22,6 +22,7 @@ > #include <linux/nvmem-provider.h> > #include <linux/regmap.h> > #include <linux/pm_runtime.h> > +#include <linux/regulator/consumer.h> > #include <linux/gpio/consumer.h> > > /* Address pointer is 16 bit. */ > @@ -67,6 +68,12 @@ > * which won't work on pure SMBus systems. > */ > > +static const char * const at24_supply_names[] = { > + "power", "i2c", > +}; > + > +#define AT24_NUM_SUPPLIES ARRAY_SIZE(at24_supply_names) > + > struct at24_client { > struct i2c_client *client; > struct regmap *regmap; > @@ -91,6 +98,8 @@ struct at24_data { > > struct gpio_desc *wp_gpio; > > + bool has_supplies; > + struct regulator_bulk_data supplies[AT24_NUM_SUPPLIES]; > /* > * Some chips tie up multiple I2C addresses; dummy devices reserve > * them for us, and we'll use them with SMBus calls. > @@ -662,6 +671,15 @@ static int at24_probe(struct i2c_client *client) > at24->client[0].client = client; > at24->client[0].regmap = regmap; > > + for (i = 0; i < AT24_NUM_SUPPLIES; i++) > + at24->supplies[i].supply = at24_supply_names[i]; > + > + err = devm_regulator_bulk_get(&at24->client[0].client->dev, > + AT24_NUM_SUPPLIES, at24->supplies); > + if (err == -EPROBE_DEFER) > + return err; > + at24->has_supplies = !err; One more thing I noticed: we should only set has_supplies to NULL if the error code returned by regulator_bulk_get is ENODEV. Other errors should break the execution of probe(). Bart > + > at24->wp_gpio = devm_gpiod_get_optional(dev, "wp", GPIOD_OUT_HIGH); > if (IS_ERR(at24->wp_gpio)) > return PTR_ERR(at24->wp_gpio); > @@ -704,14 +722,26 @@ static int at24_probe(struct i2c_client *client) > /* enable runtime pm */ > pm_runtime_set_active(dev); > pm_runtime_enable(dev); > + pm_runtime_get_sync(dev); > + if (at24->has_supplies) { > + err = regulator_bulk_enable(AT24_NUM_SUPPLIES, at24->supplies); > + if (err) { > + dev_err(dev, "Failed to enable power regulators\n"); > + pm_runtime_disable(dev); > + return err; > + } > + } > > /* > * Perform a one-byte test read to verify that the > * chip is functional. > */ > err = at24_read(at24, 0, &test_byte, 1); > - pm_runtime_idle(dev); > + pm_runtime_put(dev); > if (err) { > + if (at24->has_supplies) > + regulator_bulk_disable(AT24_NUM_SUPPLIES, > + at24->supplies); > pm_runtime_disable(dev); > return -ENODEV; > } > @@ -725,15 +755,46 @@ static int at24_probe(struct i2c_client *client) > > static int at24_remove(struct i2c_client *client) > { > + struct at24_data *at24 = i2c_get_clientdata(client); > + > pm_runtime_disable(&client->dev); > pm_runtime_set_suspended(&client->dev); > + if (at24->has_supplies) > + regulator_bulk_disable(AT24_NUM_SUPPLIES, at24->supplies); > > return 0; > } > > +static int __maybe_unused at24_suspend(struct device *dev) > +{ > + struct i2c_client *client = to_i2c_client(dev); > + struct at24_data *at24 = i2c_get_clientdata(client); > + > + if (at24->has_supplies) > + return regulator_bulk_disable(AT24_NUM_SUPPLIES, > + at24->supplies); > + > + return 0; > +} > + > +static int __maybe_unused at24_resume(struct device *dev) > +{ > + struct i2c_client *client = to_i2c_client(dev); > + struct at24_data *at24 = i2c_get_clientdata(client); > + > + if (at24->has_supplies) > + return regulator_bulk_enable(AT24_NUM_SUPPLIES, > + at24->supplies); > + > + return 0; > +} > + > +static SIMPLE_DEV_PM_OPS(at24_pm_ops, at24_suspend, at24_resume); > + > static struct i2c_driver at24_driver = { > .driver = { > .name = "at24", > + .pm = &at24_pm_ops, > .of_match_table = at24_of_match, > .acpi_match_table = ACPI_PTR(at24_acpi_ids), > }, > -- > 2.18.0 >