On 6/19/19 11:52 AM, Fabrice Gasnier wrote: > STM32 Timers support generic 3 cells PWM to encode PWM number, period and > polarity. > > Fixes: 7edf7369205b ("pwm: Add driver for STM32 plaftorm") Reviewed-by: Benjamin Gaignard <benjamin.gaignard@xxxxxx> > > Signed-off-by: Fabrice Gasnier <fabrice.gasnier@xxxxxx> > --- > drivers/pwm/pwm-stm32.c | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/drivers/pwm/pwm-stm32.c b/drivers/pwm/pwm-stm32.c > index 4f84255..740e2de 100644 > --- a/drivers/pwm/pwm-stm32.c > +++ b/drivers/pwm/pwm-stm32.c > @@ -608,6 +608,8 @@ static int stm32_pwm_probe(struct platform_device *pdev) > priv->regmap = ddata->regmap; > priv->clk = ddata->clk; > priv->max_arr = ddata->max_arr; > + priv->chip.of_xlate = of_pwm_xlate_with_flags; > + priv->chip.of_pwm_n_cells = 3; > > if (!priv->regmap || !priv->clk) > return -EINVAL;