Document the bindings used by the Renesas R-Car Gen3 RPC-IF MFD. Signed-off-by: Mason Yang <masonccyang@xxxxxxxxxxx> --- .../devicetree/bindings/mfd/mfd-renesas-rpc.txt | 40 ++++++++++++++++++++++ 1 file changed, 40 insertions(+) create mode 100644 Documentation/devicetree/bindings/mfd/mfd-renesas-rpc.txt diff --git a/Documentation/devicetree/bindings/mfd/mfd-renesas-rpc.txt b/Documentation/devicetree/bindings/mfd/mfd-renesas-rpc.txt new file mode 100644 index 0000000..668b822 --- /dev/null +++ b/Documentation/devicetree/bindings/mfd/mfd-renesas-rpc.txt @@ -0,0 +1,40 @@ +Renesas R-Car Gen3 RPC-IF MFD Device Tree Bindings +-------------------------------------------------- + +Required properties: +- compatible: should be an SoC-specific compatible value, followed by + "renesas,rcar-gen3-rpc" as a fallback. + supported SoC-specific values are: + "renesas,r8a77995-rpc" (R-Car D3) +- reg: should contain three register areas: + first for the base address of RPC-IF registers, + second for the direct mapping read mode and + third for the write buffer area. +- reg-names: should contain "regs", "dirmap" and "wbuf" +- clocks: should contain 1 entries for the module's clock +- clock-names: should contain "rpc" +- #address-cells: should be 1 +- #size-cells: should be 0 + +Example: + + rpc: rpc-if@ee200000 { + compatible = "renesas,r8a77995-rpc", "renesas,rcar-gen3-rpc"; + reg = <0 0xee200000 0 0x200>, <0 0x08000000 0 0x4000000>, + <0 0xee208000 0 0x100>; + reg-names = "regs", "dirmap", "wbuf"; + clocks = <&cpg CPG_MOD 917>; + clock-names = "rpc"; + power-domains = <&sysc R8A77995_PD_ALWAYS_ON>; + resets = <&cpg 917>; + #address-cells = <1>; + #size-cells = <0>; + + flash@0 { + compatible = "jedec,spi-nor"; + reg = <0>; + spi-max-frequency = <40000000>; + spi-tx-bus-width = <1>; + spi-rx-bus-width = <1>; + }; + }; -- 1.9.1