The Amlogic G12A has a slighly different Power Control, but uses the same address space and sysctrl registers. Signed-off-by: Neil Armstrong <narmstrong@xxxxxxxxxxxx> --- .../devicetree/bindings/power/amlogic,meson-gx-pwrc.txt | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/power/amlogic,meson-gx-pwrc.txt b/Documentation/devicetree/bindings/power/amlogic,meson-gx-pwrc.txt index 1cd050b4054c..0fdc3dd1125e 100644 --- a/Documentation/devicetree/bindings/power/amlogic,meson-gx-pwrc.txt +++ b/Documentation/devicetree/bindings/power/amlogic,meson-gx-pwrc.txt @@ -16,7 +16,9 @@ Device Tree Bindings: --------------------- Required properties: -- compatible: should be "amlogic,meson-gx-pwrc-vpu" for the Meson GX SoCs +- compatible: should be one of the following : + - "amlogic,meson-gx-pwrc-vpu" for the Meson GX SoCs + - "amlogic,meson-g12a-pwrc-vpu" for the Meson G12A SoCs - #power-domain-cells: should be 0 - amlogic,hhi-sysctrl: phandle to the HHI sysctrl node - resets: phandles to the reset lines needed for this power demain sequence -- 2.20.1