On Tue, Nov 27, 2018 at 05:48:15PM +0100, Fabrice Gasnier wrote: > Some system control registers need to be clocked, so the registers can > be accessed. Add an optional clock. > > Signed-off-by: Fabrice Gasnier <fabrice.gasnier@xxxxxx> > --- > Documentation/devicetree/bindings/mfd/syscon.txt | 1 + > 1 file changed, 1 insertion(+) > > diff --git a/Documentation/devicetree/bindings/mfd/syscon.txt b/Documentation/devicetree/bindings/mfd/syscon.txt > index 25d9e9c..a9aaa51 100644 > --- a/Documentation/devicetree/bindings/mfd/syscon.txt > +++ b/Documentation/devicetree/bindings/mfd/syscon.txt > @@ -17,6 +17,7 @@ Optional property: > - reg-io-width: the size (in bytes) of the IO accesses that should be > performed on the device. > - hwlocks: reference to a phandle of a hardware spinlock provider node. > +- clocks: phandle to the syscon clock No. Add clocks to specific bindings using syscon. If you have a node with only 'syscon', then that should be fixed. Rob