On 8/13/18 6:34 AM, Manivannan Sadhasivam wrote:
Hi Parthiban,
On Sun, Aug 12, 2018 at 02:22:13PM +0200, Parthiban Nallathambi wrote:
Actions Semi OWL family SoC's provides support for external interrupt
controller to be connected and controlled using SIRQ pins. S500, S700
and S900 provides 3 SIRQ lines and works independently for 3 external
interrupt controllers.
Signed-off-by: Parthiban Nallathambi <pn@xxxxxxx>
Signed-off-by: Saravanan Sekar <sravanhome@xxxxxxxxx>
---
.../interrupt-controller/actions,owl-sirq.txt | 46 ++++++++++++++++++++++
1 file changed, 46 insertions(+)
create mode 100644 Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
diff --git a/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt b/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
new file mode 100644
index 000000000000..4b8437751331
--- /dev/null
+++ b/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
@@ -0,0 +1,46 @@
+Actions Semi Owl SoCs SIRQ interrupt controller
+
+S500, S700 and S900 SoC's from Actions provides 3 SPI's from GIC,
+in which external interrupt controller can be connected. 3 SPI's
+45, 46, 47 from GIC are directly exposed as SIRQ. It has
+the following properties:
We should really document the driver here. What it does? and how the
hierarchy is handled with GIC? etc...
+
+- inputs three interrupt signal from external interrupt controller
+
+Required properties:
+
+- compatible: should be "actions,owl-sirq"
+- reg: physical base address of the controller and length of memory mapped.
...length of memory mapped region?
Yes it is.
+- interrupt-controller: identifies the node as an interrupt controller
+- #interrupt-cells: specifies the number of cells needed to encode an interrupt
+ source, should be 2.
+- actions,sirq-shared-reg: Applicable for S500 and S700 where SIRQ register
+ details are maintained at same offset/register.
+- actions,sirq-offset: register offset for SIRQ interrupts. When registers are
+ shared, all the three offsets will be same (S500 and S700).
+- actions,sirq-clk-sel: external interrupt controller can be either
+ connected to 32Khz or 24Mhz external/internal clock. This needs
Hertz should be specified as Hz.
+ to be configured for per SIRQ line. Failing defaults to 32Khz clock.
What value needs to be specified for selecting 24MHz clock? You should
mention the available options this property supports.
Ok, this property will be removed here and leave to default 24MHz for
all the SoC's.
+
+Example for S900:
+
+sirq: interrupt-controller@e01b0000 {
+ compatible = "actions,owl-sirq";
+ reg = <0 0xe01b0000 0 0x1000>;
could be: reg = <0x0 0xe01b0000 0x0 0x1000>;
Agreed!
+ interrupt-controller;
+ #interrupt-cells = <2>;
+ actions,sirq-clk-sel = <0 0 0>;
+ actions,sirq-offset = <0x200 0x528 0x52c>;
+};
+
+Example for S500 and S700:
+
+sirq: interrupt-controller@e01b0000 {
+ compatible = "actions,owl-sirq";
+ reg = <0 0xe01b0000 0 0x1000>;
For S500, reg base is 0xb01b0000.
Yes, agreed!
Thanks,
Parthi
Thanks
Mani
+ interrupt-controller;
+ #interrupt-cells = <2>;
+ actions,sirq-shared-reg;
+ actions,sirq-clk-sel = <0 0 0>;
+ actions,sirq-offset = <0x200 0x200 0x200>;
+};
--
2.14.4