Previous implementation uses a hard-coded register value to check if the current serial entity is the console entity. Now the lantiq serial driver uses the aliases for the index of the serial port. The lantiq danube serial dts are updated with aliases to support this. Signed-off-by: Songjun Wu <songjun.wu@xxxxxxxxxxxxxxx> --- Changes in v2: None arch/mips/boot/dts/lantiq/danube.dtsi | 2 +- arch/mips/boot/dts/lantiq/easy50712.dts | 4 ++++ 2 files changed, 5 insertions(+), 1 deletion(-) diff --git a/arch/mips/boot/dts/lantiq/danube.dtsi b/arch/mips/boot/dts/lantiq/danube.dtsi index 510be63c8bdf..73746d7577d7 100644 --- a/arch/mips/boot/dts/lantiq/danube.dtsi +++ b/arch/mips/boot/dts/lantiq/danube.dtsi @@ -74,7 +74,7 @@ reg = <0xe100a00 0x100>; }; - serial@e100c00 { + asc1: serial@e100c00 { compatible = "lantiq,asc"; reg = <0xe100c00 0x400>; interrupt-parent = <&icu0>; diff --git a/arch/mips/boot/dts/lantiq/easy50712.dts b/arch/mips/boot/dts/lantiq/easy50712.dts index 1ce20b7d05cb..452860ca1868 100644 --- a/arch/mips/boot/dts/lantiq/easy50712.dts +++ b/arch/mips/boot/dts/lantiq/easy50712.dts @@ -4,6 +4,10 @@ /include/ "danube.dtsi" / { + aliases { + serial0 = &asc1; + }; + chosen { bootargs = "console=ttyLTQ0,115200 init=/etc/preinit"; }; -- 2.11.0 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html