Hi Andrew, On 18-07-26 12:36 PM, Andrew Lunn wrote: > On Thu, Jul 26, 2018 at 12:33:05PM -0700, Arun Parameswaran wrote: >> >> >> On 18-07-26 12:20 PM, Andrew Lunn wrote: >>> On Thu, Jul 26, 2018 at 11:36:24AM -0700, Arun Parameswaran wrote: >>>> Add support for saving and restoring the 'scan control' register >>>> in the Broadcom iProc mdio mux driver. >>> >>> Hi Arun >>> >>> I don't see anything setting this register. So why is it necessary to >>> save it over suspend/resume? >>> >>> Andrew >>> >> Hi Andrew >> In the Omega SoC (only), this register was defaulted incorrectly (to use >> a test mode) by the hardware. So we added the setup of the register to >> the early bootloader (ATF). >> >> We still need to restore this register while resuming from sleep. > > Hi Arun > > It is better to not rely on the bootloader and have the driver do it. > That makes it easier for people to swap to alternative bootloaders. > > Andrew > I will make the change to set the register in the driver. Thanks Arun -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html