Hi, On Tue, Jul 24, 2018 at 4:46 PM, Matthias Kaehlcke <mka@xxxxxxxxxxxx> wrote: > The thermal zone uses spmi-temp-alarm as sensor, the trip points > correspond to the PMIC thermal stages 1 and 2. The critical trip > point at 125°C disables the partial PMIC shutdown at stage 2. > > Without an IIO input the sensor only reports a limited number of > temperatures: > > - 37°C for temperatures below 105°C > - 107°C for temperatures >= 105°C and < 125°C > - 127°C for temperatures >= 125°C > > (the numbers correspond to a stage 1 threshold of 105°C) > > Signed-off-by: Matthias Kaehlcke <mka@xxxxxxxxxxxx> > --- > Changes in v5: > - removed 'stage2-shutdown-disabled' property from spmi-temp-alarm > - updated commit message > > Changes in v4: > - updated trip point temperatures to match stage 1 and 2 ones > - disabled stage 2 shutdown > - updated commit message > > Changes in v3: > - moved 'thermal-zones' node to the beginning of the .dtsi > > Changes in v2: > - defined 'thermal-zones' node in pm8998.dtsi instead of using a label > to refer to it > - use 105°C hardware trip point as critical trip point > - reduced number of trip points to 2 > - lowered temperature of passive trip point > - updated trip point names and added labels > - updated commit message > --- > arch/arm64/boot/dts/qcom/pm8998.dtsi | 25 +++++++++++++++++++++++++ > 1 file changed, 25 insertions(+) Looks great! Reviewed-by: Douglas Anderson <dianders@xxxxxxxxxxxx> -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html