The only capability of the Armada thermal driver is currently just to read one sensor (the default one) per AP and one per CP. Actually, there is one sensor per core in the AP806 plus one sensor in the thermal IP itself. The CP110 just features one thermal sensor in its own thermal IP. This series first improves the readability of this driver, then adds support for multi-channel thermal IPs. The bindings and the device-trees are updated accordingly. Eduardo, this is a barely modified version of my previous series adding overheat interrupt support. All the interrupt-related patches have been dropped for now. It is now only rewording, reorganization and multi-sensor support being added here; there is no more dependency. As I did not receive any feedback since April, 24th I would like it to be merged for 4.19. Thank you, Miquèl Changes since v1: ================= * Added register ranges in the thermal nodes. * Added these ranges in the documentation also. * In the bindings, used the "Must be one of" formula before listing the compatibles. * Removed the overheat interrupt support that depends on another series. This work is independent. * Rebased on top of v4.18-rc1. Miquel Raynal (23): thermal: armada: remove useless register accesses thermal: armada: remove misleading comments thermal: armada: rename the initialization routine thermal: armada: dissociate a380 and cp110 ->init() hooks thermal: armada: average over samples to avoid glitches thermal: armada: convert driver to syscon register accesses thermal: armada: use the resource managed registration helper alternative thermal: armada: add multi-channel sensors support thermal: armada: remove sensors validity from the IP initialization thermal: armada: move validity check out of the read function thermal: armada: get rid of the ->is_valid() pointer dt-bindings: cp110: rename cp110 syscon file dt-bindings: ap806: prepare the syscon file to list other syscons nodes dt-bindings: cp110: prepare the syscon file to list other syscons nodes dt-bindings: ap806: add the thermal node in the syscon file dt-bindings: cp110: update documentation since DT de-duplication dt-bindings: cp110: add the thermal node in the syscon file dt-bindings: thermal: armada: add reference to new bindings arm64: dts: marvell: rename ap806 syscon node arm64: dts: marvell: move AP806/CP110 thermal nodes into a new syscon arm64: dts: marvell: add thermal-zone node in ap806 DTSI file arm64: dts: marvell: add macro to make distinction between node names arm64: dts: marvell: add thermal-zone node in cp110 DTSI file .../arm/marvell/ap806-system-controller.txt | 50 +- ...controller0.txt => cp110-system-controller.txt} | 61 ++- .../devicetree/bindings/thermal/armada-thermal.txt | 5 + arch/arm64/boot/dts/marvell/armada-ap806.dtsi | 76 ++- arch/arm64/boot/dts/marvell/armada-common.dtsi | 1 + arch/arm64/boot/dts/marvell/armada-cp110.dtsi | 37 +- drivers/thermal/armada_thermal.c | 510 +++++++++++++++------ 7 files changed, 583 insertions(+), 157 deletions(-) rename Documentation/devicetree/bindings/arm/marvell/{cp110-system-controller0.txt => cp110-system-controller.txt} (85%) -- 2.14.1 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html