On 01-06-18, 12:25, Masahiro Yamada wrote: > 2018-05-25 14:40 GMT+09:00 Viresh Kumar <viresh.kumar@xxxxxxxxxx>: > > The cooling device properties, like "#cooling-cells" and > > "dynamic-power-coefficient", should either be present for all the CPUs > > of a cluster or none. If these are present only for a subset of CPUs of > > a cluster then things will start falling apart as soon as the CPUs are > > brought online in a different order. For example, this will happen > > because the operating system looks for such properties in the CPU node > > it is trying to bring up, so that it can register a cooling device. > > > > Add such missing properties. > > > > Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> > > > Applied to linux-uniphier. > > I had already sent a PR for v4.18-rc1 before I received this patch. > Please wait for v4.19-rc1. Sure, no hurry. Though I thought this kind of fixes can go in 4.18-rc2 as well, isn't it ? -- viresh -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html