On Fri, Apr 20, 2018 at 12:04:42PM +0200, Jean-Jacques Hiblot wrote: > The TAS6424 incorporates both DC-load and AC-load diagnostics which are > used to determine the status of the load. The DC diagnostics runs when any > channel is directed to leave the Hi-Z state and enter the MUTE or PLAY > state. > The DC diagnostics are turned on by default but if a fast startup without > diagnostics is required the DC diagnostics can be bypassed by adding the > property "disable-auto-diagnostics". This is making me think we should be smarter here and either only run the diagnostics once during boot or provide a user control for the diagnostics. It seems like something that is more of a runtime software decision than something that's fixed in hardware design, is there anything about the hardware design that'd make it impossible to run diagnostics? > + if (tas6424->no_auto_diags) { > + /* > + * Disable DC auto-diagnostics to save time when channel leave > + * Hi-Z state > + */ > + ret = regmap_update_bits(tas6424->regmap, > + TAS6424_DC_DIAG_CTRL1, > + 0xff, TAS6424_LDGBYPASS); This could just be exposed to userspace as a simple switch control couldn't it? I do note that it masks more bits than it sets though...