During a short period when the bus voltage is switched from 3.3v to 1.8v, (to enumerate UHS mode), the mmc module is disabled and the mmc IO lines are kept in a state according to the programmed pad mux pull type. According to 4.2.4.2 Timing to Switch Signal Voltage in "SD Specifications Part 1 Physical Layer Specification Version 5.00 February 22, 2016", the host should hold CLK low for at least 5ms. In order to keep the card line low during voltage switch, the pad mux of mmc1_clk line should be configured to pull down. This is specific only to dra71-evm (and not all dra72 based boards) since mmc1_clk line in dra71-evm is not connected to an external pullup. Signed-off-by: Kishon Vijay Abraham I <kishon@xxxxxx> --- arch/arm/boot/dts/dra71-evm.dts | 13 +++++++++++++ 1 file changed, 13 insertions(+) diff --git a/arch/arm/boot/dts/dra71-evm.dts b/arch/arm/boot/dts/dra71-evm.dts index 64363f75c01a..ebc4bbae981e 100644 --- a/arch/arm/boot/dts/dra71-evm.dts +++ b/arch/arm/boot/dts/dra71-evm.dts @@ -50,6 +50,19 @@ }; }; +&dra7_pmx_core { + mmc1_pins_default: mmc1_pins_default { + pinctrl-single,pins = < + DRA7XX_CORE_IOPAD(0x3754, PIN_INPUT_PULLDOWN | MUX_MODE0) /* mmc1_clk.clk */ + DRA7XX_CORE_IOPAD(0x3758, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_cmd.cmd */ + DRA7XX_CORE_IOPAD(0x375c, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat0.dat0 */ + DRA7XX_CORE_IOPAD(0x3760, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat1.dat1 */ + DRA7XX_CORE_IOPAD(0x3764, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat2.dat2 */ + DRA7XX_CORE_IOPAD(0x3768, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat3.dat3 */ + >; + }; +}; + &i2c1 { status = "okay"; clock-frequency = <400000>; -- 2.11.0 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html