The R-Car H2 hardware manual states that Tc = –40°C to +105°C. The thermal sensor has an accuracy of ±5°C and there can be a temperature difference of 1 or 2 degrees between Tjmax and the thermal sensor due to the location of the latter. This means that 95°C is a safer value to use. Fixes: a8b805f3606f7af7 ("ARM: dts: r8a7790: enable to use thermal-zone") Signed-off-by: Chris Paterson <chris.paterson2@xxxxxxxxxxx> --- arch/arm/boot/dts/r8a7790.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm/boot/dts/r8a7790.dtsi b/arch/arm/boot/dts/r8a7790.dtsi index 450bfc0e9796a557..ed9a68538a554001 100644 --- a/arch/arm/boot/dts/r8a7790.dtsi +++ b/arch/arm/boot/dts/r8a7790.dtsi @@ -168,7 +168,7 @@ trips { cpu-crit { - temperature = <115000>; + temperature = <95000>; hysteresis = <0>; type = "critical"; }; -- 1.9.1 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html