On 02/03/2014 04:06 PM, Arnd Bergmann wrote: > On Friday 31 January 2014, Michal Simek wrote: >> +Optional properties: >> +- clock-frequency : Frequency of clock in Hz >> +- xlnx,wdt-enable-once : 0 - Watchdog can be restarted >> + 1 - Watchdog can be enabled just once >> +- xlnx,wdt-interval : Watchdog timeout interval in 2^<val> clock cycles, >> + <val> is integer from 8 to 31. >> + > > The latter two don't really seem to be xilinx specific, it would be > reasonable to have a standard watchdog binding that mandates a common > format for them. > > I'm not sure about the enable-once flag, which seems to just map to the > "nowayout" watchdog option that is not a hardware feature at all > and should probably be kept as a software setting only, rather than > settable through DT. If it is kept, it should have a standard name and > get turned into a boolean (present/absent) property rather than a > 0/1 integer property. > > The interval should really be specified in terms of seconds or miliseconds, > not in clock cycles. Intention wasn't to fix binding but document current one which is in mainline for a long time. Apart of this - yes, wdt-enable-once is nowayout and wdt-interval should be timeout is seconds, and clock-frequency should go out and use CCF for getting clock. Thanks, Michal -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html