On Thu, Aug 03, 2017 at 11:46:50AM +0300, Mykola Kostenok wrote: > It's add support for cooling device creation to > aspeed-pwm-tacho. > Cooling device could be bound to a thermal zone > for the thermal control. > > v1 -> v2: > - Fix commit message. > v2 -> v3: > Pointed out by Rob Herring: > - Put cooling-levels under fan subnodes. > > Signed-off-by: Mykola Kostenok <c_mykolak@xxxxxxxxxxxx> > Acked-by: Rob Herring <robh@xxxxxxxxxx> Applied to hwmon-next (removed version information from description) Thanks, Guenter > --- > Documentation/devicetree/bindings/hwmon/aspeed-pwm-tacho.txt | 9 +++++++++ > 1 file changed, 9 insertions(+) > > diff --git a/Documentation/devicetree/bindings/hwmon/aspeed-pwm-tacho.txt b/Documentation/devicetree/bindings/hwmon/aspeed-pwm-tacho.txt > index cf44605..367c820 100644 > --- a/Documentation/devicetree/bindings/hwmon/aspeed-pwm-tacho.txt > +++ b/Documentation/devicetree/bindings/hwmon/aspeed-pwm-tacho.txt > @@ -11,6 +11,8 @@ Required properties for pwm-tacho node: > > - #size-cells : should be 1. > > +- #cooling-cells: should be 2. > + > - reg : address and length of the register set for the device. > > - pinctrl-names : a pinctrl state named "default" must be defined. > @@ -28,12 +30,17 @@ fan subnode format: > Under fan subnode there can upto 8 child nodes, with each child node > representing a fan. If there are 8 fans each fan can have one PWM port and > one/two Fan tach inputs. > +For PWM port can be configured cooling-levels to create cooling device. > +Cooling device could be bound to a thermal zone for the thermal control. > > Required properties for each child node: > - reg : should specify PWM source port. > integer value in the range 0 to 7 with 0 indicating PWM port A and > 7 indicating PWM port H. > > +- cooling-levels: PWM duty cycle values in a range from 0 to 255 > + which correspond to thermal cooling states. > + > - aspeed,fan-tach-ch : should specify the Fan tach input channel. > integer value in the range 0 through 15, with 0 indicating > Fan tach channel 0 and 15 indicating Fan tach channel 15. > @@ -50,6 +57,7 @@ pwm_tacho_fixed_clk: fixedclk { > pwm_tacho: pwmtachocontroller@1e786000 { > #address-cells = <1>; > #size-cells = <1>; > + #cooling-cells = <2>; > reg = <0x1E786000 0x1000>; > compatible = "aspeed,ast2500-pwm-tacho"; > clocks = <&pwm_tacho_fixed_clk>; > @@ -58,6 +66,7 @@ pwm_tacho: pwmtachocontroller@1e786000 { > > fan@0 { > reg = <0x00>; > + cooling-levels = /bits/ 8 <125 151 177 203 229 255>; > aspeed,fan-tach-ch = /bits/ 8 <0x00>; > }; > -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html