On Sun, Jun 25, 2017 at 06:53:24PM +0530, Anand Moon wrote: > Hi Willy, > > On 24 June 2017 at 02:39, Willy Wolff <willy.mh.wolff@xxxxxxxxx> wrote: > > Odroid XU*-familly boards has thermal sensors per A15 cores, but the actual > > thermal-zones define only cooling-maps action for cpu0. > > > > If the application is running on all cores but core4 (first core of the A15 > > cluster), the CPU can reach high temperature without any proper cooling > > action. > > > > As already discus in prior mail, and on IRC, it's a quit big code > > duplication, but I don't found the write way to express that in a better > > way. > > > > The situation for this board is that we have multiple sensors, but > > matching cooling devices for these sensors act for the same physical > > device (FAN and A15 cluster, as each core of the cluster share the same > > frequency). > > In fact, of-thermal.c:473:thermal_zone_of_sensor_register() can't use > > multiple sensors for one single thermal zone. > > This patch follow the path taken in arch/arm/boot/dts/qcom-apq8084.dtsi:97 > > > > I'm interested to extending the thermal driver, but it will takes time. > > So this is a workaround before refactoring the driver. > > If somebody knows how to write it better, any advice and suggestions > > are more than welcome. > > > > Also, the comment for cpu_alert4 in cooling-maps definition is not > > accurate, 11 steps for A15 correspond to 700MHz, not 600MHz. > > > > [snip] > > Few point to from my side. > > 1: We should also increase the trip points temperature so that it can > throttle at high temperature. It is not related to this problem. If you wish to address different problem related to non-optimal choice of temperature, then please send a separate patch explaining chosen values. > 2: We should also increase the tips from 4 to 8 to support different > cluster of cpu's. There are 4 CPU thermal zones on Exynos5422. What do you want to expand? > 3: To avoid duplication of cooling-maps we can make tmu sensor work > differently for cluster of cpu's > tmu_cpu0: handle pwm-fan control. > tmu_cpu1: handle cpu[0-3] cpufreq mapping. > tmu_cpu2: handle cpu[4-7] cpufreq mapping. I miss the point behind this. Why fan should work only when CPU4 (tmu_cpu0) is heated and not CPU5-7 (rest of cpu tmu's)? Best regards, Krzysztof > tmu_gpu: handle gpu (mali) cpu throttle. > > Please share your thought on this new approach. > > I generally test using linaro's pm-qa and most of the time the test case fails > # git clone git://git.linaro.org/tools/pm-qa.git > # make -C thermal check > > -Best Regards > -Anand Moon -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html