On Mon, Mar 13, 2017 at 3:15 PM, Rafał Miłecki <rafal@xxxxxxxxxx> wrote: > On 03/13/2017 08:14 PM, Andrew Lunn wrote: >> >> On Mon, Mar 13, 2017 at 07:48:26PM +0100, Rafa?? Mi??ecki wrote: >>> >>> On 03/12/2017 06:10 PM, Andrew Lunn wrote: >>>>> >>>>> + chosen { >>>>> + bootargs = "console=ttyS0,115200 earlycon"; >>>> >>>> >>>> Using bootargs to pass the serial settings has been deprecated for a >>>> while. Please use stdout-path instead. >>> >>> >>> I tried following patch with my SR400ac (I put Archer C5 aside for now). >> >> >> Hi Rafael >> >> Take a look at for example the bcm911360k.dts >> >> aliases { >> serial0 = &uart3; >> }; >> >> chosen { >> stdout-path = "serial0:115200n8"; >> }; >> >> You need an alias to the serial device you want to us, and you should >> list the speed, parity, bits etc. > > > That was actually my first try (just with s/uart3/uart0) and I got the same > problem. I have a similar line in the bcm953012k.dts, and the serial there works for me. -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html