Hi Chen-Yu, On 21/02/2017 05:44, Chen-Yu Tsai wrote: > On Tue, Feb 14, 2017 at 5:41 PM, Quentin Schulz > <quentin.schulz@xxxxxxxxxxxxxxxxxx> wrote: >> The X-Powers AXP20X and AXP22X PMICs can have a battery as power supply. >> >> This patch adds the battery power supply driver to get various data from >> the PMIC, such as the battery status (charging, discharging, full, >> dead), current max limit, current current, battery capacity (in >> percentage), voltage max and min limits, current voltage and battery >> capacity (in Ah). >> >> This battery driver uses the AXP20X/AXP22X ADC driver as PMIC data >> provider. >> >> Signed-off-by: Quentin Schulz <quentin.schulz@xxxxxxxxxxxxxxxxxx> >> Acked-by: Jonathan Cameron <jic23@xxxxxxxxxx> >> Acked-by: Maxime Ripard <maxime.ripard@xxxxxxxxxxxxxxxxxx> [...] >> +static int axp20x_set_constant_charge_current(struct axp20x_batt_ps *axp_batt, >> + int charge_current) >> +{ >> + if (axp_batt->axp_id == AXP209_ID) >> + charge_current = (charge_current - 300000) / 100000; >> + else >> + charge_current = (charge_current - 300000) / 150000; >> + >> + if (charge_current > AXP20X_CHRG_CTRL1_TGT_CURR || charge_current < 0) >> + return -EINVAL; > > I would add a check or warn if the value to be programmed exceeds that returned > by power_supply_get_battery_info. Completely agree on a warning. > A charge current exceeding the limits of the > battery is potentially disastrous. The battery may be destroyed or even burst > into flames and explode, taking the board and anything nearby with it. Otherwise > Yes, I understand. Maybe I'm seeing this ability to set the (max) constant current charge the wrong way. Here is what I think: If we limit the max constant charge current with a DT property, it would require a DT rebuild when changing the battery (i.e. if an end-user decides to change the battery with a bigger constant charge current, he has to recompile the DT to change the DT value). What I can suggest is the following: - set the max constant charge current and the default constant charge current from the DT property, - allow the user to change the constant charge current via sysfs within minimal-DT value range, - allow the user to set max constant charge current via sysfs (and print a warning as well when setting it), then the user can set a higher constant charge current, That would require a two steps modification with a printed warning. "Safer" but does not remove the ability to change the constant charge current in the case of battery swapping/changing. > Acked-by: Chen-Yu Tsai <wens@xxxxxxxx> > > Speaking of power_supply_get_battery_info, is it merged or ready to be merged? > v7 under way IIRC. Thanks, Quentin -- Quentin Schulz, Free Electrons Embedded Linux and Kernel engineering http://free-electrons.com -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html