On 19/02/17 02:23, Eduardo Valentin wrote:
On Mon, Feb 13, 2017 at 05:01:58PM +0800, Dawei Chien wrote:
Hi, Matthias,
On Thu, 2017-02-09 at 22:25 +0100, Matthias Brugger wrote:
On 02/08/2017 06:31 AM, Dawei Chien wrote:
Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
However, Currently thermal driver don't need read TEMP_MSR3 since
thermal controller only use 3 sensors for each thermal bank.
Signed-off-by: Dawei Chien <dawei.chien@xxxxxxxxxxxx>
---
Actually the commit message should state:
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
...and get backported to v4.9 and v4.10.
Reviewed-by: Matthias Brugger <matthias.bgg@xxxxxxxxx>
Regards,
Matthias
Thank you for your review. I would add below commit message on next
version. However, currently 8173 thermal driver would not read TEMP_MSR3
since thermal driver only use 3 sensors on each bank, this patch would
not effect temperature.
Only if thermal driver use 4 sensors on any thermal bank, would read
third sensor two times, and lose fourth sensor of vale.
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
Please send a new version with the tag in the commit message.
And don't forget to add stable@xxxxxxxxxxxxxxx so that the fix ends up
in the older kernels as well.
Regards,
Matthias
--