Re: [PATCH v1 07/12] scsi: ufs: add option to change default UFS power management level

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 2016-12-13 12:04, Rob Herring wrote:
On Mon, Dec 12, 2016 at 04:54:20PM -0800, Subhash Jadavani wrote:
UFS device and link can be put in multiple different low power modes hence
UFS driver supports multiple different low power modes. By default UFS
driver selects the default (optimal) low power mode (which gives moderate
power savings and have relatively less enter and exit latencies) but
we might have to tune this default power mode for different chipset
platforms to meet the low power requirements/goals. Hence this patch
adds option to change default UFS low power mode (level).

Reviewed-by: Yaniv Gardi <ygardi@xxxxxxxxxxxxxx>
Signed-off-by: Subhash Jadavani <subhashj@xxxxxxxxxxxxxx>
---
 .../devicetree/bindings/ufs/ufshcd-pltfrm.txt      | 10 ++++++
 drivers/scsi/ufs/ufshcd-pltfrm.c                   | 14 ++++++++
drivers/scsi/ufs/ufshcd.c | 39 ++++++++++++++++++++++
 drivers/scsi/ufs/ufshcd.h                          |  4 +--
 4 files changed, 65 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/ufs/ufshcd-pltfrm.txt b/Documentation/devicetree/bindings/ufs/ufshcd-pltfrm.txt
index a99ed55..c3836c5 100644
--- a/Documentation/devicetree/bindings/ufs/ufshcd-pltfrm.txt
+++ b/Documentation/devicetree/bindings/ufs/ufshcd-pltfrm.txt
@@ -41,6 +41,14 @@ Optional properties:
-lanes-per-direction : number of lanes available per direction - either 1 or 2.
 			  Note that it is assume same number of lanes is used both
directions at once. If not specified, default is 2 lanes per direction. +- rpm-level : UFS Runtime power management level. Following PM levels are supported: + 0 - Both UFS device and Link in active state (Highest power consumption)
+			  1 - UFS device in active state but Link in Hibern8 state
+			  2 - UFS device in Sleep state but Link in active state
+ 3 - UFS device in Sleep state and Link in hibern8 state (default PM level)
+			  4 - UFS device in Power-down state and Link in Hibern8 state
+ 5 - UFS device in Power-down state and Link in OFF state (Lowest power consumption) +- spm-level : UFS System power management level. Allowed PM levels are same as rpm-level.

This looks like you are putting policy for Linux into DT.

What I would expect to see here is disabling of states that don't work
due to some h/w limitation. Otherwise, it is a user decision for what
modes to go into. Also, I think link and device states should be
separate.

Yes, generally default level (3) is good enough (and recommended) for all platforms and most likely user is only expected to change this if they see issues (most H/W) on their platform or they want even more aggressive power state (level-4 or level-5) and ready to take the performance hit associated with resume latencies.

Also, I think it is better to keep Link and device states tied, one reason is that we can't keep device in sleep/active state when Link is in OFF state.


Rob

--
The Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum,
a Linux Foundation Collaborative Project
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx