Re: [PATCH] ARM: dts: exynos: Only Odroid XU3-family boards use DTSI with CPU thermal nodes

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




Hi Krzysztof ,

On 9 May 2016 at 11:49, Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx> wrote:
> Include the CPU thermal nodes directly in Odroid XU3-family common DTS
> because it is the only user of it. Keeping it in separate DTSI node does
> not bring benefits because:
> 1. It is not re-usable on other non-fan boards (fan is referenced),
> 2. It won't be re-used on future Odroid XU board because different
>    CPU cluster behavior.
>
> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx>
> ---
>  arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi      | 103 ---------------------
>  arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi |  94 ++++++++++++++++++-
>  2 files changed, 92 insertions(+), 105 deletions(-)
>  delete mode 100644 arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
>
> diff --git a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
> deleted file mode 100644
> index 3e4c4ad96d63..000000000000
> --- a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
> +++ /dev/null
> @@ -1,103 +0,0 @@
> -/*
> - * Device tree sources for Exynos5422 thermal zone
> - *
> - * Copyright (c) 2015 Lukasz Majewski <l.majewski@xxxxxxxxxxx>
> - *                     Anand Moon <linux.amoon@xxxxxxxxx>
> - *
> - * This program is free software; you can redistribute it and/or modify
> - * it under the terms of the GNU General Public License version 2 as
> - * published by the Free Software Foundation.
> - *
> - */
> -
> -#include <dt-bindings/thermal/thermal.h>
> -
> -/ {
> -       thermal-zones {
> -               cpu0_thermal: cpu0-thermal {
> -                       thermal-sensors = <&tmu_cpu0 0>;
> -                       polling-delay-passive = <250>;
> -                       polling-delay = <0>;
> -                       trips {
> -                               cpu_alert0: cpu-alert-0 {
> -                                       temperature = <50000>; /* millicelsius */
> -                                       hysteresis = <5000>; /* millicelsius */
> -                                       type = "active";
> -                               };
> -                               cpu_alert1: cpu-alert-1 {
> -                                       temperature = <60000>; /* millicelsius */
> -                                       hysteresis = <5000>; /* millicelsius */
> -                                       type = "active";
> -                               };
> -                               cpu_alert2: cpu-alert-2 {
> -                                       temperature = <70000>; /* millicelsius */
> -                                       hysteresis = <5000>; /* millicelsius */
> -                                       type = "active";
> -                               };
> -                               cpu_crit0: cpu-crit-0 {
> -                                       temperature = <120000>; /* millicelsius */
> -                                       hysteresis = <0>; /* millicelsius */
> -                                       type = "critical";
> -                               };
> -                               /*
> -                                * Exyunos542x support only 4 trip-points
> -                                * so for these polling mode is required.
> -                                * Start polling at temperature level of last
> -                                * interrupt-driven trip: cpu_alert2
> -                                */
> -                               cpu_alert3: cpu-alert-3 {
> -                                       temperature = <70000>; /* millicelsius */
> -                                       hysteresis = <10000>; /* millicelsius */
> -                                       type = "passive";
> -                               };
> -                               cpu_alert4: cpu-alert-4 {
> -                                       temperature = <85000>; /* millicelsius */
> -                                       hysteresis = <10000>; /* millicelsius */
> -                                       type = "passive";
> -                               };
> -
> -                       };
> -                       cooling-maps {
> -                               map0 {
> -                                    trip = <&cpu_alert0>;
> -                                    cooling-device = <&fan0 0 1>;
> -                               };
> -                               map1 {
> -                                    trip = <&cpu_alert1>;
> -                                    cooling-device = <&fan0 1 2>;
> -                               };
> -                               map2 {
> -                                    trip = <&cpu_alert2>;
> -                                    cooling-device = <&fan0 2 3>;
> -                               };
> -                               /*
> -                                * When reaching cpu_alert3, reduce CPU
> -                                * by 2 steps. On Exynos5422/5800 that would
> -                                * be: 1500 MHz and 1100 MHz.
> -                                */
> -                               map3 {
> -                                    trip = <&cpu_alert3>;
> -                                    cooling-device = <&cpu0 0 2>;
> -                               };
> -                               map4 {
> -                                    trip = <&cpu_alert3>;
> -                                    cooling-device = <&cpu4 0 2>;
> -                               };
> -
> -                               /*
> -                                * When reaching cpu_alert4, reduce CPU
> -                                * further, down to 600 MHz (11 steps for big,
> -                                * 7 steps for LITTLE).
> -                                */
> -                               map5 {
> -                                    trip = <&cpu_alert4>;
> -                                    cooling-device = <&cpu0 3 7>;
> -                               };
> -                               map6 {
> -                                    trip = <&cpu_alert4>;
> -                                    cooling-device = <&cpu4 3 11>;
> -                               };
> -                       };
> -               };
> -       };
> -};
> diff --git a/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi b/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> index 2a4e10bc8801..ff05041835e5 100644
> --- a/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> +++ b/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> @@ -1,9 +1,11 @@
>  /*
>   * Hardkernel Odroid XU3 board device tree source
>   *
> - * Copyright (c) 2014 Collabora Ltd.
>   * Copyright (c) 2013 Samsung Electronics Co., Ltd.
>   *             http://www.samsung.com
> + * Copyright (c) 2014 Collabora Ltd.
> + * Copyright (c) 2015 Lukasz Majewski <l.majewski@xxxxxxxxxxx>
> + *                    Anand Moon <linux.amoon@xxxxxxxxx>
>   *
>   * This program is free software; you can redistribute it and/or modify
>   * it under the terms of the GNU General Public License version 2 as
> @@ -16,7 +18,6 @@
>  #include <dt-bindings/sound/samsung-i2s.h>
>  #include "exynos5800.dtsi"
>  #include "exynos5422-cpus.dtsi"
> -#include "exynos5422-cpu-thermal.dtsi"
>
>  / {
>         memory {
> @@ -54,6 +55,95 @@
>                 #cooling-cells = <2>;
>                 cooling-levels = <0 130 170 230>;
>         };
> +
> +       thermal-zones {
> +               cpu0_thermal: cpu0-thermal {
> +                       thermal-sensors = <&tmu_cpu0 0>;
> +                       polling-delay-passive = <250>;
> +                       polling-delay = <0>;
> +                       trips {
> +                               cpu_alert0: cpu-alert-0 {
> +                                       temperature = <50000>; /* millicelsius */
> +                                       hysteresis = <5000>; /* millicelsius */
> +                                       type = "active";
> +                               };
> +                               cpu_alert1: cpu-alert-1 {
> +                                       temperature = <60000>; /* millicelsius */
> +                                       hysteresis = <5000>; /* millicelsius */
> +                                       type = "active";
> +                               };
> +                               cpu_alert2: cpu-alert-2 {
> +                                       temperature = <70000>; /* millicelsius */
> +                                       hysteresis = <5000>; /* millicelsius */
> +                                       type = "active";
> +                               };
> +                               cpu_crit0: cpu-crit-0 {
> +                                       temperature = <120000>; /* millicelsius */
> +                                       hysteresis = <0>; /* millicelsius */
> +                                       type = "critical";
> +                               };
> +                               /*
> +                                * Exynos542x supports only 4 trip-points
> +                                * so for these polling mode is required.
> +                                * Start polling at temperature level of last
> +                                * interrupt-driven trip: cpu_alert2
> +                                */
> +                               cpu_alert3: cpu-alert-3 {
> +                                       temperature = <70000>; /* millicelsius */
> +                                       hysteresis = <10000>; /* millicelsius */
> +                                       type = "passive";
> +                               };
> +                               cpu_alert4: cpu-alert-4 {
> +                                       temperature = <85000>; /* millicelsius */
> +                                       hysteresis = <10000>; /* millicelsius */
> +                                       type = "passive";
> +                               };
> +
> +                       };
> +                       cooling-maps {
> +                               map0 {
> +                                    trip = <&cpu_alert0>;
> +                                    cooling-device = <&fan0 0 1>;
> +                               };
> +                               map1 {
> +                                    trip = <&cpu_alert1>;
> +                                    cooling-device = <&fan0 1 2>;
> +                               };
> +                               map2 {
> +                                    trip = <&cpu_alert2>;
> +                                    cooling-device = <&fan0 2 3>;
> +                               };
> +                               /*
> +                                * When reaching cpu_alert3, reduce CPU
> +                                * by 2 steps. On Exynos5422/5800 that would
> +                                * be: 1500 MHz and 1100 MHz.
> +                                */
> +                               map3 {
> +                                    trip = <&cpu_alert3>;
> +                                    cooling-device = <&cpu0 0 2>;
> +                               };
> +                               map4 {
> +                                    trip = <&cpu_alert3>;
> +                                    cooling-device = <&cpu4 0 2>;
> +                               };
> +
> +                               /*
> +                                * When reaching cpu_alert4, reduce CPU
> +                                * further, down to 600 MHz (11 steps for big,
> +                                * 7 steps for LITTLE).
> +                                */
> +                               map5 {
> +                                    trip = <&cpu_alert4>;
> +                                    cooling-device = <&cpu0 3 7>;
> +                               };
> +                               map6 {
> +                                    trip = <&cpu_alert4>;
> +                                    cooling-device = <&cpu4 3 11>;
> +                               };
> +                       };
> +               };
> +       };
> +
>  };
>
>  &bus_wcore {
> --
> 1.9.1
>

Could you defer this patch, during my testing with pm-qa from linaro.

git://git.linaro.org/tools/pm-qa.git

When their is running of thermal test case cpu usage reaches around
300+ percentage
and some time's the Odroid XU4 hang down.
-------------------------------------------------------------------------
[ 1028.056619] CPU4: shutdown
[ 1148.510372] IRQ54 no longer affine to CPU5
[ 1148.511864] CPU5: shutdown
[ 1268.921073] IRQ55 no longer affine to CPU6
[ 1268.922564] CPU6: shutdown
[ 1389.271930] cpu cpu4: Failed to find opp_table: -19
[ 1389.301668] IRQ56 no longer affine to CPU7
[ 1389.303132] CPU7: shutdown
[ 1510.538424] cpu cpu4: opp_list_debug_create_link: Failed to create link
[ 1510.543762] cpu cpu4: _add_opp_dev: Failed to register opp debugfs (-12)
[ 1510.550625] cpu cpu7: opp_list_debug_create_link: Failed to create link
[ 1510.557037] cpu cpu7: _add_opp_dev: Failed to register opp debugfs (-12)
[ 1510.664649] cpu cpu5: cpufreq_init: failed to get clk: -2
[ 1510.720567] cpu cpu6: cpufreq_init: failed to get clk: -2
[ 1510.788280] cpu cpu7: cpufreq_init: failed to get clk: -2
root@odroidxu4l:/home/odroid/study/linaro/pm-qa# killall heat_cpu

-------------------------------------------------------------------------
And some time I observed that the board will poweroff on reaching
temperature 120 degree C.
when I am compiling the kernel with or above. make -j8
-------------------------------------------------------------------------
root@odroidxu4l:~#  * Starting NTP server ntpd                           [ OK ]
saned disabled; edit /etc/default/saned
[ 4118.924470] thermal thermal_zone3: critical temperature reached(121
C),shutting down
[ 4119.014327] thermal thermal_zone3: critical temperature reached(121
C),shutting down

Broadcast message from root@odroidxu4l
        (unknown) at 20:41 ...

The system is going down for power off NOW!

Broadcast message from root@odroidxu4l
        (unknown) at 20:41 ...

The system is going down for power off NOW!
[ 4119.431386] thermal thermal_zone3: critical temperature reached(121
C),shutting down
[ 4120.206709] thermal thermal_zone3: critical temperature reached(120
C),shutting down

Broadcast message from root@odroidxu4l
        (unknown) at 20:41 ...

The system is going down for power off NOW!
wait-for-state stop/waiting
[ 4157.574406] reboo

U-Boot 2016.03-00665-g563d8d9-dirty (Apr 04 2016 - 22:27:07 +0930) for
ODROID-XU3

CPU:   Exynos5422 @ 800 MHz
Model: Odroid XU3 based on EXYNOS5422
Board: Odroid XU3 based on EXYNOS5422
Type:  xu4
DRAM:  2 GiB
MMC:   EXYNOS DWMMC: 0, EXYNOS DWMMC: 1
*** Warning - bad CRC, using default environment
-------------------------------------------------------------------------
Once the thermal issue is fixed we can redo this changes.

Best Regards
-Anand Moon
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]
  Powered by Linux