On Wednesday 06 January 2016 07:55 PM, Rob Herring wrote:
On Wed, Jan 06, 2016 at 12:37:35PM +0000, Mark Brown wrote:
On Wed, Jan 06, 2016 at 05:49:22PM +0530, Laxman Dewangan wrote:
On Wednesday 06 January 2016 05:48 PM, Mark Brown wrote:
* PGP Signed by an unknown key
On Wed, Jan 06, 2016 at 11:45:22AM +0530, Laxman Dewangan wrote:
Enhanced transient response (ETR) will affect the configuration of CKADV.
+-maxim,junction-temp-warning: Junction temp warning on which device generates
+ warning interrupts.
This needs to specify what the values are - it looks like it's raw
register values but I'd have expected from this that it'd be an actual
temperature.
I tried to roundoff to the next higher threshold when supported value (120
or 140 degC) is not provided in driver. But it is fine to me to specify the
possible value setting here and DT binding doc. Will do on next patch.
I don't really mind which you use so long as the documentation is clear.
I prefer that degrees are used rather than register values.
From DT/platform, any values can be passed. Driver will round off to
next higher side.
The document details will only provide what is supported by the PMIC device.
E.g. It can pass to ,<=120C and driver will set nearest threshold which
is 120C.
If it is >120C then it will set to 140C.
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html